Section 8

Communication Interface

8-23

Figure 8.16 shows the remote I/O module as it comes mounted in the
component enclosure for 9/260 controls.

Figure 8.16

Remote I/O Module Mounted in the Component Enclosure

Remote I/O

Communication Module

CPU

Module

Enclosure

19441

Mounting the Remote I/O Module in the Component Enclosure

If you ordered the remote I/O module with your 9/260 control, it comes

already mounted in the component enclosure. If you have ordered the

remote I/O module separately, use this procedure to mount the remote I/O

module in the component enclosure.

Important: You can not use the remote I/O module in a 9/260 system that

contains either a 9/Series Data Highway Plus communication module or a

9/Series MMS/Ethernet communication module. A 9/260 system can

contain only one Remote I/O, DH+, or MMS/Ethernet module.

ATTENTION: To prevent damage to the module, wear an ESD

wristband while you unpack and install the module. Connect the

wristband to the ground screw on the control’s component

enclosure.

8.9.2

9/260 Remote I/O Module