Connecting the 3-axis Servo Module
4B-36
BAT/TP (TB1) Touch Probe Connector.
The analog servo module receives touch probe feedback through the
connector labeled BAT/TP (TB1). Figure 4B.32 shows the location of the
BAT/TP connector and lists the terminal assignments.
Figure 4B.32
Connector BAT/TP, 6 Plug-type Terminal Block Connections.
Terminal
No.
Signal
Description
Signal Destination
1
Not Used
2
Not Used
3
+5V
Probe Power
Touch Probe
4
PRB_FIRE
Probe Fired Signal
1
Servo Module
5
PE
Touch Probe Common
Touch Probe
6
Shield
Probe Shield
connect at module
only
1
The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as
defined by the AMP parameter PROBE TRANSITION.
Refer to the 9/Series
CNC 9/230, 9/260, and 9/290 AMP Reference Manual, publication
8520-6.4, for more information.
Important: The touch probe connector supports only +5V probing device
applications.
P3 5V dc Encoder Power Connector
The analog servo module receives +5V dc power directly from the main
power supply through connector P3. This +5V dc power is used only for
powering the encoder. If the EXT Power connection on the encoder
termination panel is used or if the 15V dc encoder power is used the
connection to P3 is not needed. Figure 4B.33 shows an end view of
connector P3 and lists the pin assignments. For details on this connection
refer to the section on the main power supply connections on page 4D-4.