beautypg.com

Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 479

background image

Section 9A

Operator Interface

9A-12

Jumper JP3 on the operator panel keyboard interface is used to determine
if the keyboard interface module is attached to a monochrome or color

operator panel (note these keyboard configurations are different). This

jumper comes preset from the factory in the correct position for your

operator panel. Adjustment of this jumper should only be made when

replacing the operator panel keyboard interface module.

Set the color or monochrome operator panel jumper (JP3) to match the

type of operator panel you have. The following table illustrates proper

setting of JP3.

Jumper JP3 Setting

For this Operator Panel:

JP3

MOP

COP

Color and Flat Panel Operator Panels

JP3

MOP

COP

Monochrome Operator Panel

JP1

JP2

JP3

JP

3

M

O

P

CO

P

JP3 shown configured for

color operator panel.

Monitor intensity is controlled by adjusting the contrast on monochrome
and color CRT systems. No intensity adjustments are available for the flat

operator panels.

Monitor intensity adjustment is typically not required on the operator

panels as they are adjusted to an acceptable level before shipping from the

factory. In the event that you think you must alter the monitor intensity use

the following procedure:

9A.2.6

Keyboard Interface

Jumper JP3

9A.2.7

Adjusting Monitor Intensity