Message
Description
SHARED AXIS NOT IN PROCESS
You have attempted to position a shared axis (or recouple a shared dual axis) not currently
available to the requesting process. A shared axis can only be positioned by the process
currently controlling the shared axis.
SHARED SPINDLE CONTENTION
This is a run-time decode error. A process attempted to activate an exclusive-use spindle mode
or change the spindle speed when another process was using it. The process goes into cycle
stop.
SHIFT AWAY FROM ENDPOINT
When a cylindrical grinder cycle (G84 or G85) is programmed with a shift and plunge, and the
shift increment does not move towards the cycle endpoint, this message is generated. The shift
increment must move towards the cycle endpoint.
SHIFT VALUE HAS TOO MANY DIGITS
You have used incorrect search string syntax in the PAL search monitor utility.
SKIPPING SOURCE NOT INCLUDED MODULE(S)
When you downloaded your PAL program the source code for some modules was not included.
The ODS software can decide to not include the source on selected modules when it determines
their is not sufficient memory on the control to hold both the PAL image and the source code.
The PAL search monitor utility will not monitor any PAL modules that do not have their source
code downloaded.
SLASH NOT ALLOWED
An error occurred in G05 DH+ communications block.
SLAVE AXIS LETTER CANNOT BE PROGRAMMED
An attempt was made, when using dual axes, to program the slave’s axis letter.
SPINDLE CONFIGURATION ERROR
An attempt was made to configure a spindle that did not have a servo board identified in AMP to
indicate to which board the spindle is connected. The spindle must be included in the
number--of--motors AMP parameter for the board the spindle is on.
SPINDLE ERROR, AMP FIRST SPINDLE 1ST
AMP order of spindles must be spindle 1, spindle 2, spindle 3.
SPINDLE ERROR, AMP SECOND SPINDLE 2ND
AMP order of spindles must be spindle 1, spindle 2, spindle 3.
SPINDLE ERROR, AMP THIRD SPINDLE 3RD
AMP order of spindles must be spindle 1, spindle 2, spindle 3.
SPINDLE IS CLAMPED
An attempt was made to program a block containing a spindle code other than an M05 while the
PAL servo clamp request flag for the spindle was set.
SPINDLE MODES INCOMPATIBLE
An attempt was made to enter virtual mode when the spindle that is used for this mode is
synchronized as the follower spindle or an attempt was made to perform end face milling during
synchronization.
SPINDLE MOTOR SPEED TOO HIGH
When using a 1326 motor as a spindle, feedback resolution combined with your configured
maximum spindle speed would return feedback counts faster than the control can reliably
decode. Either reduce the maximum configured spindle speed, or reduce the configured
feedback counts for the spindle in AMP.
SPINDLE MUST BE THE LAST SERVO
When the system is AMPed, the spindle must be assigned to the first available port after all axes
have been assigned.
SPINDLE NOT ASSIGNED
A spindle axis was AMPed, but not assigned to any process.
SPINDLE ORDER ERROR, AMP AUX. 2 SECOND
AMP order of spindles must be primary spindle, aux. spindle 2, aux. spindle 3.
SPINDLE ORDER ERROR, AMP AUX. 3 THIRD
AMP order of spindles must be primary spindle, aux. spindle 2, aux. spindle 3.
SPINDLE ORDER ERROR, AMP PRIMARY 1ST
AMP order of spindles must be primary spindle, aux. spindle 2, aux. spindle 3.
SPINDLE SYNC NOT CONFIGURED
The programmer attempted to enter synchronized spindle mode before it was configured in
AMP.
SPINDLE SYNC UNAVAILABLE THIS PROCESS
An attempt was made to enter synchronized spindle mode on a dual--process control when the
process was not yet configured for both spindles in the synchronized pair.
SQUARE ROOT OF NEGATIVE ERROR
Internal math error has occurred; contact Allen-Bradley customer support services.
SQUARE ROOT OF NEGATIVE INVALID
An attempt was made to determine the square root of a negative number using the calculator or
through a paramacro SQRT command.
STORED PASSWORD LIST TO BACKUP
This message appears after the password list has been successfully stored to the control’s
backup memory.