10a.3.2 digital i/o specifications – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 549
I/O Interface
Section 10A
10A-26
Table 10A.N lists the power requirements for the 4 types of digital I/O.
Table 10A.N
Digital I/O Power Requirements
Item
Digital I/O Types
E151, E152, E153
E154
Rated Input Voltage
115/230 V ac 50/60 Hz
24 V dc
Input Voltage Range
85-132/170-265 V ac 47-63 Hz
10-30 V dc
Power Consumption
Less than 15 VA
Less than 9 VA
Fuse Rating
315mA/250V
1.6A/250V
Fuse Type
Glass-tube-filled (
f
6.35
´
31.8 mm)
Power ON Indicating LED
Lights up when +5V is supplied to the internal circuit
Connection
Terminal Block
Table 10A.O lists the input specifications for the 4 types of digital I/O. All
input circuits include optical isolation as well as filtering to guard against
high voltage transients from external input devices.
Table 10A.O
Digital I/O Input Specifications
Item
Digital I/O Types
E151
E152
E153
E154
Number of Inputs
20 Input Terminals (pins: A01-A10, B01-B10)
Rated Input Voltage
85-132 V ac 50/60 Hz
170-265 V ac 50/60 Hz 10-30 V dc
Operating Voltage
ON
85-132 V ac
170-265 V ac
10-30 V dc
OFF
Less than 30 V ac
Less than 50 V ac
Less than 4 V dc
Leakage Current at OFF
Less than 2mA
Less than 1mA
Input Current
Approximately 8mA
Approx. 4mA at 12 V dc
Approx. 8mA at 24 V dc
Maximum Inrush Current
Less than 0.8A
Response
ON to OFF
3-13 msec
1
4-8 msec
1
OFF to ON
9-18 msec
1
4-8 msec
1
Operation Indication
LED ON when power is ON
Connection
Terminal Block
Number of Common Points
6 points per 20 input points
2
Dielectric Strength
Higher than 1500V
3
1
Excluding digital filter time.
2
All common lines are internally connected to each other.
3
Across input terminal - control logic circuit.
10A.3.2
Digital I/O Specifications