System ready faults, Led indicators – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 648
Section 13A
Connecting 8520 Digital Drive Systems
13A-14
This section discusses faults and how they are detected on the 8520 digital
servo amplifier.
System Ready Faults
The system checks that the servo amplifier is ready using two methods:
System Ready Connector (TB3)
The System Ready (on TB3) contact makes sure that the control board of
the servo amplifier is ready, the power circuit of the DC bus is ready, and
the system relay is closed.
Table 13A.C
System Ready Contact Ratings
DC
AC
24V dc @ 1.4 A (max. 30 W)
230V ac @ 1.4 A (max. 30 W)
Axis status output (CNA1, CNA2, and CNA3)
The Axis status output contact is connected to the servo module and is
checked by the servo module’s CPU on a per axis basis. If this contact is
not active, the servo module recognizes that the amplifier is in a fault
condition and sends the message “SERVO AMPLIFIER FAULT” sent to
the control. This is pre-wired through servo cable CN20.
LED Indicators
Table 13A.D through Table 13A.F lists the symbol, indication, and color of
the 8520 digital servo amplifier fault and ready status indicators (note the
LED indicators are numbered on the 3AX-D servo amplifier).
Table 13A.D
1AX-D (1 axis) Servo Amplifier Indicators
Symbol
Fault or Ready Indication
Color
OT
Over Temperature
Red
UV
Bus Undervoltage
Yellow
OC
Over Current
Red
AXF
Axis 1 Fault
Red
RDY
System Ready
Green
OV
Bus Overvoltage
Red
CVF
Control Voltage Fault
Red
EAX1
Axis 1 Enable
Green
13A.4
8520 Digital Servo Amplifier
Fault Indicators
Circuit
breaker
TB3
TB1
TB4
CNA1
TB2
Location of
LEDs