15a.4.5 mtb panel i/o diagnostics screen – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 732

Section 15A
Troubleshooting The Control
15A-22
If a MTB Panel I/O device is selected on the Ring I/O screen and the
{DISPLY} softkey is pressed, the MTB I/O Diagnostics screen appears.
Figure 15A.8 is an example of this screen.
Figure 15A.8
MTB Panel I/O Diagnostics Screen
MTB PANEL I/O
SETUP MODE
DEVICE NO. 01
ON =
IN
01 PW 03 PW 05 PW 07 PW 09 PW
11 PW 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48 49 50
OUT
01 GD 03 GD 05 GD 07 GD 09 GD
11 GD 13 GD 15 GD 17 18 19 20
21 22 23 24 25 26
The device number of the selected MTB Panel I/O device appears under
the “MTB PANEL I/O” heading. This will be a decimal number from 00
to 03.
This screen displays the input and output pin assignments that correspond
to the input and output connectors on the MTB Panel I/O module.
If an input or output pin is “ON”, it appears in inverse video. This is a real
time display, and its response is limited only by delays in screen updates.
The following abbreviated symbols may appear:
PW = power connection
GD = ground connection
If more than one MTB Panel I/O device is on the I/O Ring, a diagnostics
screen for each of these devices can be displayed. To display a diagnostics
screen for the next MTB panel I/O device on the ring, press and hold the
[SHIFT] key and press the [DOWN-ARROW] key.
Pressing the exit softkey (up arrow) at any time displays the Ring I/O
Menu screen.
15A.4.5
MTB Panel I/O
Diagnostics Screen