Image file types, Upgrading software, Upgrading the boot code – Brocade TurboIron 24X Series Configuration Guide User Manual
Page 84

50
Brocade TurboIron 24X Series Configuration Guide
53-1003053-01
Image file types
TurboIron#verify md5 secondary 01c410d6d153189a4a5d36c955653861
TurboIron#.........................Done
Size = 2044830, MD5 01c410d6d153189a4a5d36c955653862
Verification FAILED.
In the previous example, the codes did not match, and verification failed. If verification succeeds,
the output will look like this.
TurboIron#verify md5 secondary 01c410d6d153189a4a5d36c955653861
TurboIron#.........................Done
Size = 2044830, MD5 01c410d6d153189a4a5d36c955653861
Verification SUCEEDED.
The following examples show this process for SHA-1 and CRC32 algorithms.
TurboIron#verify sha secondary 49d12d26552072337f7f5fcaef4cf4b742a9f525
TurboIron#.........................Done
Size = 2044830, sha 49d12d26552072337f7f5fcaef4cf4b742a9f525
Verification SUCCEEDED.
and
TurboIron#verify crc32 secondary b31fcbc0
TurboIron#.........................Done
Size = 2044830, CRC32 b31fcbc0
Verification SUCCEEDED.
Image file types
This section lists the boot and flash image file types supported on the TurboIron X Series of
switches and how to install them. For information about a specific version of code, refer to the
release notes.
Upgrading software
Use the following procedures to upgrade the software.
Upgrading the boot code
Follow the steps given below to upgrade the boot code.
1. Place the new boot code on a TFTP server to which the device has access.
2. Enter the following command at the Privileged EXEC level of the CLI to copy the boot code from
the TFTP server into flash memory:
•
copy tftp flash <ip-addr> <image-file-name> bootrom
TABLE 16
Software image files
Product
Boot image
1
1.
Flash image
TurboIron X Series
TRZxxxxx.bin
TISxxxxx.bin (Layer 2)