Setting the system clock – Brocade TurboIron 24X Series Configuration Guide User Manual
Page 63

Brocade TurboIron 24X Series Configuration Guide
29
53-1003053-01
Configuring basic system parameters
To display information about NTPv4 status, enter the following command.
Syntax: show sntp status
The following table describes the information displayed by the show sntp status command.
Setting the system clock
In addition to NTPv4 support, switches and routers also allow you to set the system time counter.
The time counter setting is not retained across power cycles and is not automatically synchronized
with an NTPv4 server. The counter merely starts the system time and date clock with the time and
date you specify.
TABLE 12
Output from the show sntp associations command
This field...
Displays...
(leading character)
One or both of the following:
*
Synchronized to this peer
~
Peer is statically configured
address
IP address of the peer
ref clock
IP address of the peer reference clock
st
NTP stratum level of the peer
when
Amount of time since the last NTP packet was received from the peer
poll
Poll interval in seconds
delay
Round trip delay in milliseconds
disp
Dispersion in seconds
TABLE 13
Output from the show sntp status command
This field...
Indicates...
unsynchronized
System is not synchronized to an NTP peer.
synchronized
System is synchronized to an NTP peer.
stratum
NTP stratum level of this system
reference clock
IP Address of the peer (if any) to which the unit is synchronized
precision
Precision of this system's clock (in Hz)
reference time
Reference time stamp
clock offset
Offset of clock to synchronized peer
root delay
Total delay along the path to the root clock
root dispersion
Dispersion of the root path
peer dispersion
Dispersion of the synchronized peer
TurboIron#show sntp status
Clock is unsynchronized, stratum = 0, no reference clock
precision is 2**0
reference time is 0 .0
clock offset is 0.0 msec, root delay is 0.0 msec
root dispersion is 0.0 msec, peer dispersion is 0.0 msec