beautypg.com

Brocade TurboIron 24X Series Configuration Guide User Manual

Page 1086

background image

1052

Brocade TurboIron 24X Series Configuration Guide

53-1003053-01

Syslog messages

Alert

MAC Authentication failed for
on (No VLAN
Info received from RADIUS server)

RADIUS authentication was successful for
the specified on the
specified ; however, dynamic
VLAN assignment was enabled for the port,
but the RADIUS Access-Accept message did
not include VLAN information. This is
treated as an authentication failure.

Alert

MAC Authentication failed for
on (Port is
already in another radius given vlan)

RADIUS authentication was successful for
the specified on the
specified ; however, the RADIUS
Access-Accept message specified a VLAN
ID, although the port had previously been
moved to a different RADIUS-assigned
VLAN. This is treated as an authentication
failure.

Alert

MAC Authentication failed for
on (RADIUS
given vlan does not exist)

RADIUS authentication was successful for
the specified on the
specified ; however, the RADIUS
Access-Accept message specified a VLAN
that does not exist in the configuration. This
is treated as an authentication failure.

Alert

MAC Authentication failed for
on (RADIUS
given VLAN does not match with TAGGED
vlan)

Multi-device port authentication failed for
the on a tagged port
because the packet with this MAC address
as the source was tagged with a VLAN ID
different from the RADIUS-supplied VLAN
ID.

Alert

Management module at state changed from
to .

Indicates a state change in a management
module.
The can be one of the
following:

active

standby

crashed

coming-up

unknown

Alert

OSPF LSA Overflow, LSA Type =

Indicates an LSA database overflow.
The parameter indicates the
type of LSA that experienced the overflow
condition. The LSA type is one of the
following:

1 – Router

2 – Network

3 – Summary

4 – Summary

5 – External

Alert

OSPF Memory Overflow

OSPF has run out of memory.

Alert

Power supply , , failed

A power supply has failed.
The is the power supply number.
The describes where the failed
power supply is in the chassis.

TABLE 176