beautypg.com

Commands on switch a (master node), Commands on switch b – Brocade TurboIron 24X Series Configuration Guide User Manual

Page 331

background image

Brocade TurboIron 24X Series Configuration Guide

297

53-1003053-01

Metro Ring Protocol (MRP)

Commands on Switch A (master node)

The following commands configure a VLAN for the ring. The ring VLAN must contain both of the
node interfaces with the ring. Add these interfaces as tagged interfaces, since the interfaces also
must be in each of the customer VLANs configured on the node.

TurboIron(config)#vlan 2

TurboIron(config-vlan-2)#tag ethernet 1 to 2

TurboIron(config-vlan-2)#metro-ring 1

TurboIron(config-vlan-2-mrp-1)#name “Metro A”

TurboIron(config-vlan-2-mrp-1)#master

TurboIron(config-vlan-2-mrp-1)#ring-interface ethernet 1 ethernet 2

TurboIron(config-vlan-2-mrp-1)#enable

TurboIron(config-vlan-2-mrp-1)#exit

TurboIron(config-vlan-2)#exit

The following commands configure the customer VLANs. The customer VLANs must contain both
the ring interfaces as well as the customer interfaces.

TurboIron(config)#vlan 30

TurboIron(config-vlan-30)#tag ethernet 1 to 2

TurboIron(config-vlan-30)#tag ethernet 3

TurboIron(config-vlan-30)#exit

TurboIron(config)#vlan 40

TurboIron(config-vlan-40)#tag ethernet 1 to 2

TurboIron(config-vlan-40)#tag ethernet 4

TurboIron(config-vlan-40)#exit

The following commands configure topology group 1 on VLAN 2. The master VLAN is the one that
contains the MRP configuration. The member VLANs use the MRP parameters of the master VLAN.
The control interfaces (the ones shared by the master VLAN and member VLAN) also share MRP
state.

TurboIron(config)#topology-group 1

TurboIron(config-topo-group-1)#master-vlan 2

TurboIron(config-topo-group-1)#member-vlan 30

TurboIron(config-topo-group-1)#member-vlan 40

Commands on Switch B

The commands for configuring Switches B, C, and D are similar to the commands for configuring
Switch A, with two differences: the nodes are not configured to be the ring master. Omitting the
master command is required for non-master nodes.

TurboIron(config)#vlan 2

TurboIron(config-vlan-2)#tag ethernet 1 to 2

TurboIron(config-vlan-2)#metro-ring 1

TurboIron(config-vlan-2-mrp-1)#name “Metro A”

TurboIron(config-vlan-2-mrp-1)#ring-interface ethernet 1 ethernet 2

TurboIron(config-vlan-2-mrp-1)#enable

TurboIron(config-vlan-2)#exit

TurboIron(config)#vlan 30

TurboIron(config-vlan-30)#tag ethernet 1 to 2

TurboIron(config-vlan-30)#tag ethernet 3

TurboIron(config-vlan-30)#exit

TurboIron(config)#vlan 40

TurboIron(config-vlan-40)#tag ethernet 1 to 2

TurboIron(config-vlan-40)#tag ethernet 4

TurboIron(config-vlan-40)#exit