sFlow

Syntax: show sflow

This command shows the following information.

TABLE 50

sFlow information

This field...

Displays...

sFlow services

The feature state, which can be one of the following:

disabled

enabled

sFlow agent IP address

The IP address that sFlow is using in the agent_address field of packets
sent to the collectors. Refer to

“Source address”

on page 243.

Collector

The collector information. The following information is displayed for each
collector:

IP address

UDP port

If more than one collector is configured, the line above the collectors
indicates how many have been configured.

Polling interval

The port counter polling interval.

Configured default sampling rate

The configured global sampling rate. If you changed the global sampling
rate, the value you entered is shown here. The actual rate calculated by
the software based on the value you entered is listed on the next line,
”Actual default sampling rate”.

...continued from previous page...

Port Sampling Rates

-------------------

Port 4, configured rate=512, actual rate=512, Subsampling factor=1

Port 1, configured rate=512, actual rate=512, Subsampling factor=1

Port 20, configured rate=3000, actual rate=8192, Subsampling factor=16

Port 19, configured rate=512, actual rate=512, Subsampling factor=1

Port 18, configured rate=512, actual rate=512, Subsampling factor=1

Port 17, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 16, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 15, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 14, configured rate=1500, actual rate=2048, Subsampling factor=4

Port 13, configured rate=512, actual rate=512, Subsampling factor=1

Port 12, configured rate=512, actual rate=512, Subsampling factor=1

Port 11, configured rate=512, actual rate=512, Subsampling factor=1

Port 10, configured rate=512, actual rate=512, Subsampling factor=1

Port 1, configured rate=10000, actual rate=32768, Subsampling factor=1

Port 26, configured rate=512, actual rate=512, Subsampling factor=1

Port 25, configured rate=512, actual rate=512, Subsampling factor=1

Port 15, configured rate=512, actual rate=512, Subsampling factor=1

Port 12, configured rate=512, actual rate=512, Subsampling factor=1

Port 11, configured rate=512, actual rate=512, Subsampling factor=1

Port 10, configured rate=512, actual rate=512, Subsampling factor=1

Port 9, configured rate=512, actual rate=512, Subsampling factor=1

Port 8, configured rate=512, actual rate=512, Subsampling factor=1

Port 7, configured rate=1000, actual rate=2048, Subsampling factor=4

Port 6, configured rate=512, actual rate=512, Subsampling factor=1

Port 5, configured rate=512, actual rate=512, Subsampling factor=1

Port 4, configured rate=512, actual rate=512, Subsampling factor=1

Port 3, configured rate=512, actual rate=512, Subsampling factor=1

Port 2, configured rate=1000, actual rate=2048, Subsampling factor=4