25

53-1003053-01

Configuring basic system parameters

TurboIron(config)#snmp-server enable traps holddown-time 30

The command in this example changes the holddown time for SNMP traps to 30 seconds. The
device waits 30 seconds to allow convergence in STP and OSPF before sending traps to the SNMP
trap receiver.

Syntax: [no] snmp-server enable traps holddown-time

The <secs> parameter specifies the number of seconds and can be from 1 – 600 (ten minutes).
The default is 60 seconds.

Disabling SNMP traps

TurboIron X Series devices come with SNMP trap generation enabled by default for all traps. You
can selectively disable one or more of the following traps.

NOTE

By default, all SNMP traps are enabled at system startup.

Layer 2 traps
The following traps are generated on devices running Layer 2 software:

SNMP authentication keys

Power supply failure

Fan failure

Cold start

Link up

Link down

Bridge new root

Bridge topology change

Locked address violation

Layer 3 traps
The following traps are generated on devices running Layer 3 software:

SNMP authentication key

Power supply failure

Fan failure

Cold start

Link up

Link down

Bridge new root

Bridge topology change

Locked address violation

BGP4

OSPF

VRRP