beautypg.com

Brocade TurboIron 24X Series Configuration Guide User Manual

Page 491

background image

Brocade TurboIron 24X Series Configuration Guide

457

53-1003053-01

Configuring IP parameters – Layer 3 Switches

Telnet packets
To specify the lowest-numbered IP address configured on a virtual interface as the device source
for all Telnet packets, enter commands such as the following.

TurboIron(config)#int loopback 2

TurboIron(config-lbif-2)#ip address 10.0.0.2/24

TurboIron(config-lbif-2)#exit

TurboIron(config)#ip telnet source-interface loopback 2

The commands in this example configure loopback interface 2, assign IP address 10.0.0.2/24 to
the interface, then designate the interface as the source for all Telnet packets from the Layer 3
Switch.

Syntax: ip telnet source-interface ethernet [| loopback | ve ]

The parameter is a loopback interface or virtual interface number. If you specify an
Ethernet port, the is the port number.

The following commands configure an IP interface on an Ethernet port and designate the address
port as the source for all Telnet packets from the Layer 3 Switch.

TurboIron(config)#interface ethernet 4

TurboIron(config-if-4)#ip address 10.157.22.110/24

TurboIron(config-if-4)#exit

TurboIron(config)#ip telnet source-interface ethernet 4

TACACS/TACACS+ packets
To specify the lowest-numbered IP address configured on a virtual interface as the device source
for all TACACS/TACACS+ packets, enter commands such as the following.

TurboIron(config)#int ve 1

TurboIron(config-vif-1)#ip address 10.0.0.3/24

TurboIron(config-vif-1)#exit

TurboIron(config)#ip tacacs source-interface ve 1

The commands in this example configure virtual interface 1, assign IP address 10.0.0.3/24 to the
interface, then designate the interface as the source for all TACACS/TACACS+ packets from the
Layer 3 Switch.

Syntax: ip tacacs source-interface ethernet [ | loopback | ve ]

The parameter is a loopback interface or virtual interface number. If you specify an
Ethernet port, the is the port number.

RADIUS packets
To specify the lowest-numbered IP address configured on a virtual interface as the device source
for all RADIUS packets, enter commands such as the following.

TurboIron(config)#int ve 1

TurboIron(config-vif-1)#ip address 10.0.0.3/24

TurboIron(config-vif-1)#exit

TurboIron(config)#ip radius source-interface ve 1

The commands in this example configure virtual interface 1, assign IP address 10.0.0.3/24 to the
interface, then designate the interface as the source for all RADIUS packets from the Layer 3
Switch.

Syntax: ip radius source-interface ethernet | loopback | ve