beautypg.com

Brocade TurboIron 24X Series Configuration Guide User Manual

Page 75

background image

Brocade TurboIron 24X Series Configuration Guide

41

53-1003053-01

Configuring basic port parameters

TurboIron(config)#interface ethernet 1

TurboIron(config-if-e10000-1)#no link-error-disable 10 3 10

Displaying ports configured with port flap dampening

Ports that have been disabled due to the port flap dampening feature are identified in the output of
the show link-error-disable command. The following shows an example output.

Use the show link-error-disable all command to display the ports with the port flap dampening
feature enabled.

For TurboIron X Series devices, the output of the command shows the following.

Table 15

defines the port flap dampening statistics displayed by the show link-error-disable all

command.

Syntax: show link-error-disable [all]

Also, in TurboIron X Series devices, the show interface command indicates if the port flap
dampening feature is enabled on the port.

TABLE 15

Output of show link-error-disable

This column...

Displays...

Port #

The port number.

Threshold

The number of times the port link state will go from up to down and
down to up before the wait period is activated.

Sampling-Time

The number of seconds during which the specified toggle threshold can
occur before the wait period is activated.

Shutoff-Time

The number of seconds the port will remain disabled (down) before it
becomes enabled. A zero (0) indicates that the port will stay down until
an administrative override occurs.

State

The port state can be one of the following:

Idle – The link is normal and no link state toggles have been
detected or sampled.

Down – The port is disabled because the number of sampled errors
exceeded the configured threshold.

Err – The port sampled one or more errors.

Counter

If the port state is Idle, this field displays N/A.

If the port state is Down, this field shows the remaining value of the
shutoff timer.

If the port state is Err, this field shows the number of errors
sampled.

TurboIron#show link-error-disable

Port 1 is forced down by link-error-disable.

TurboIron#show link-error-disable all

Port -----------------Config--------------- ------Oper----

# Threshold Sampling-Time Shutoff-Time State Counter

----- --------- ------------- ------------ ----- -------

11 3 120 600 Idle N/A

12 3 120 500 Down 424