30
Brocade TurboIron 24X Series Configuration Guide
53-1003053-01
Configuring basic system parameters
NOTE
You can synchronize the time counter with your NTPv4 server time by entering the sntp sync
command from the Privileged EXEC level of the CLI.
NOTE
Unless you identify an NTPv4 server for the system time and date, you will need to re-enter the time
and date following each reboot.
For more details about NTPv4, refer to
“Specifying a Simple Network Time Protocol (NTPv4) server”
To set the system time and date to 10:15:05 on October 15, 2003, enter the following command.
TurboIron#clock set 10:15:05 10-15-2003
Syntax: [no] clock set <hh:mm:ss> |
By default, switches and routers do not change the system time for daylight saving time. To enable
daylight saving time, enter the following command.
TurboIron(config)#clock summer-time
Syntax: clock summer-time
Although NTPv4 servers typically deliver the time and date in Greenwich Mean Time (GMT), you can
configure the device to adjust the time for any one-hour offset from GMT or for one of the following
U.S. time zones:
•
US Pacific
•
Alaska
•
Aleutian
•
Arizona
•
Central
•
East-Indiana
•
Eastern
•
Hawaii
•
Michigan
•
Mountain
•
Pacific
•
Samoa
To change the time zone to Australian East Coast time (which is normally 10 hours ahead of GMT),
enter the following command.
TurboIron(config)#clock timezone gmt gmt+10
Syntax: clock timezone gmt gmt | us <time-zone>
You can enter one of the following values for
•
US time zones (us): alaska, aleutian, arizona, central, east-indiana, eastern, hawaii, michigan,
mountain, pacific, samoa.
•
GMT time zones (gmt): gmt+0:00 to gmt+12:00 in increments of 1, and gmt-0:00 to gmt-12:00
in decrements of 1 are supported.