NOTE

You can synchronize the time counter with your NTPv4 server time by entering the sntp sync
command from the Privileged EXEC level of the CLI.

NOTE

Unless you identify an NTPv4 server for the system time and date, you will need to re-enter the time
and date following each reboot.

For more details about NTPv4, refer to

“Specifying a Simple Network Time Protocol (NTPv4) server”

on page 28.

To set the system time and date to 10:15:05 on October 15, 2003, enter the following command.

TurboIron#clock set 10:15:05 10-15-2003

Syntax: [no] clock set <hh:mm:ss> | |

By default, switches and routers do not change the system time for daylight saving time. To enable
daylight saving time, enter the following command.

TurboIron(config)#clock summer-time

Syntax: clock summer-time

Although NTPv4 servers typically deliver the time and date in Greenwich Mean Time (GMT), you can
configure the device to adjust the time for any one-hour offset from GMT or for one of the following
U.S. time zones:

US Pacific

Alaska

Aleutian

Arizona

Central

East-Indiana

Eastern

Hawaii

Michigan

Mountain

Pacific

Samoa

To change the time zone to Australian East Coast time (which is normally 10 hours ahead of GMT),
enter the following command.

TurboIron(config)#clock timezone gmt gmt+10

Syntax: clock timezone gmt gmt | us <time-zone>

You can enter one of the following values for :

US time zones (us): alaska, aleutian, arizona, central, east-indiana, eastern, hawaii, michigan,
mountain, pacific, samoa.

GMT time zones (gmt): gmt+0:00 to gmt+12:00 in increments of 1, and gmt-0:00 to gmt-12:00