Sntrapopticalmonitoringerror, Sntrapxfpsfpincompatibleop tics, Sntraptmloggingstart – Brocade Unified IP MIB Reference (Supporting FastIron Releases 07.5.00 and 08.0.10) User Manual
Page 748: Sntraptmloggingstop, Sntraptmloggingrestart
722
Unified IP MIB Reference
53-1003106-01
Proprietary traps
67
snTrapOpticalMonitoringError
brcdIp.0.1005
NOTE: This trap is also
supported on the
FastIron devices.
snAgGblTrapMessage
Informati
onal
An error occurred during optical
monitoring.
Samples trap message:
OPTICAL MONITORING:
sys_create_timer failed, slot
OPTICAL MONITORING:
sys_set_timer failed, slot
OPTICAL MONITORING: THRESHOLDS
READ FAILED, port
OPTICAL MONITORING: AUX AD
TYPE READ FAILED, port
OPTICAL MONITORING: INT UNMASK
ALL WRITE FAILED, port
OPTICAL MONITORING: INT MASK
WRITE FAILED, port
OPTICAL MONITORING: OPTICAL
INT MASK WRITE FAILED, port
OPTICAL MONITORING: port
sys_create_timer failed
OPTICAL MONITORING: port
sys_create_timer2 failed
OPTICAL MONITORING: port
failed
OPTICAL MONITORING: port
latched flags(
OPTICAL MONITORING: port
failed
snTrapXfpSfpIncompatibleOp
tics
brcdIp.0.1009
snAgGblTrapMessage
Alerts
The optics are incompatible with the port
configuration.
snTrapTMLoggingStart
brcdIp.0.1015
snAgGblTrapMessage
Informati
onal
Traffic Manager logging started, triggerred
by an event.
snTrapTMLoggingStop
brcdIp.0.1016
snAgGblTrapMessage
Informati
onal
Traffic Manager logging stopped because
the storage is full.
snTrapTMLoggingRestart
brcdIp.0.1017
snAgGblTrapMessage
Informati
onal
Traffic Manager logging restarted after the
log was cleared.
Trap name and number
Varbinds
Severity