Unified IP MIB Reference

229

53-1003106-01

System temperature table

11

System temperature table

This section displays the SNMP MIB objects for temperature readings on the Brocade NetIron MLX,
Brocade MLXe, Brocade NetIron XMR, Brocade NetIron CES, Brocade NetIron CER series, and on
the FastIron devices.

For stacking devices, refer to

“System stacking temperature table”

on page 230. The system

temperature table shows temperature reading information for each module’s temperature sensor.

System temperature threshold table

The following table lists the temperature levels of the fan settings.

NOTE

The new MP card MR2 supports all the objects in the System temperature threshold table. The
MP-MR2 is supported only on the Brocade NetIron XMR, Brocade NetIron MLX, and Brocade MLXe
devices.

Name, OID, and syntax

Access

Description

snAgentTempTable
brcdIp.1.1.2.13.1

None

The table that displays the temperature reading for each module’s
temperature sensor. Note that temperature readings are displayed
only for those modules that have temperature sensors.

snAgentTempSlotNum
brcdIp.1.1.2.13.1.1.1
Syntax: Integer32

None

The slot number of the module to which the temperature sensor is
attached.

snAgentTempSensorId
brcdIp.1.1.2.13.1.1.2
Syntax: Integer32

None

The identification number of the module’s temperature sensor.
The following applies to the Management modules:

Sensor 1 – The intake temperature.

Sensor 2 – The exhaust-side temperature.

snAgentTempSensorDescr
brcdIp.1.1.2.13.1.1.3
Syntax: Display string

Read-only

The description of the temperature sensor.

snAgentTempValue
brcdIp.1.1.2.13.1.1.4
Syntax: Integer

Read-only

The temperature reading for the temperature sensor. This value is
displayed in units of 0.5º Celsius.
Valid values: 110 – 250

Name, OID, and syntax

Access

Description

snAgentTempThresholdTa
ble
brcdIp.1.1.2.13.2

None

The table lists the temperature threshold levels for four speeds of fan
settings:

low

medium

medium-high

high

snAgentTempThresholdM
odule
brcdIp.1.1.2.13.2.1.1
Syntax: Integer

None

The module in the system for which threshold levels represented by
this row are applicable.

This manual is related to the following products: