Switch port information
8
snSwIfInfoGigType
(continued)
•
sfpCWDM1610nm100Km(24) - 1Gbps CWDM fiber, with a
wavelength 1610nm, reach 100 kms
•
m1000BaseLHX(25) - 1Gbps fiber, with a special wavelength
transceiver (150km)
•
m1000BaseLMC(35) - Link Media Copper
•
mXFP10000BaseSR(36) - 10GBASE fiber, 850nm serial pluggable
XFP optic (LC), target range 300m over MMF
•
mXFP10000BaseLR(37) - 10GBASE fiber, 1310nm serial pluggable
XFP optic (LC) for up to 10km over SMF
•
mXFP10000BaseER(38) - 10GBASE fiber, 1550nm serial pluggable
XFP optic (LC) for up to 40km over SMF
•
mXFP10000BaseSW(39) - not used
•
mXFP10000BaseLW(40) - not used
•
mXFP10000BaseEW(41) - not used
•
mXFP10000BaseCX4(42) - 10GBASE-CX4, XFP module,15m, CX4
connector
•
mXFP10000BaseZR(43) - 1550nm serial pluggable XFP optic (LC)
for up to 80km over SMF
•
mXFP10000BaseZRD(44) - 10GBASE-ZR DWDM, XFP optic, 80km
•
mXFP10000BaseSRSW(46) - same as mXFP10000BaseSR(36)
•
mXFP10000BaseLRLW(47) - same as mXFP10000BaseLR(37)
•
mXFP10000BaseEREW(48) - same as mXFP10000BaseER(38)
•
mCFP100GBaseSR10(145) - 100GbE CFP optic (MPO 2x12), SR10,
for distances up to 100m over MMF
•
mCFP100GBaseLR4(146) - 100GbE CFP optic (SC), LR4, for
distances up to 10 km over SMF
•
mCFP100GBaseER4(147) - 100GbE CFP optic, ER4, for distances
up to 40 km over SMF
•
mCFP100GBase10x10g2Km(148) - 100GbE CFP optic (LC), 10x10,
for distances up to 2 km over SMF
•
mCFP100GBase10x10g10Km(149) - 100GbE CFP optic (LC),
10x10, for distances up to 10 km over SMF
•
qSFP40000BaseSR4(150) - SR proper value for 40G
•
qSFP40000Base10KmLR4(151) - LR proper vallue for 40G
•
notApplicable(255) - a non-gigabit port
snSwIfFastSpanPortEnab
le
brcdIp.1.1.3.3.5.1.22
Syntax: Integer
Read-write
Indicates if fast span is enabled on the port:
•
disabled(0)
•
enabled(1)
snSwIfFastSpanUplinkEn
able
brcdIp.1.1.3.3.5.1.23
Syntax: Integer
Read-write
Indicates if fast span uplink is enabled on the port:
•
disabled(0)
•
enabled(1)
snSwIfVlanId
brcdIp.1.1.3.3.5.1.24
Syntax: Integer
Read-only
Shows the ID of a VLAN of which this port is a member. Port must be
untagged.
Valid values: 0 – 4095; where 0 means an invalid VLAN ID value, which is
returned for tagged ports. Reading is valid only for untagged and dual
mode. Writing is valid for only dual mode.
Name, OID, and syntax
Access
Description