136
Unified IP MIB Reference
53-1003106-01
Agent global group
5
Name, OID, and syntax
Access
Description
snAgReload
brcdIp.1.1.2.1.1
Syntax: Integer
Read-write
Reboots the agent.
The following values can only be read:
•
other(1) – Agent is in unknown or other state.
•
running(2) – Agent is running.
•
busy(4) – Reload is not allowed at this time as flash is busy.
The following value can be written:
•
reset(3) – Do a hard reset.
The agent returns a response before the action occurs. This object
requires a password to be set for the snAgGblPassword object.
snAgEraseNVRAM
brcdIp.1.1.2.1.2
Syntax: Integer
Read-write
Erases the NVRAM of the agent. This object can have one of the following
values:
•
normal(1) – NVRAM is not being erased.
•
error(2) – Either the erase operation failed or the flash memory is
bad.
•
erasing(4) – NVRAM is being erased. If the process starts, you
cannot set this object to erase(3) until the process is finished and
the value of this object is either normal(1) or error(2).
•
busy(5) – Operation is not allowed at this time as flash is busy.
The following value can be written:
•
erase(3) – Erase operation.
The agent returns a response even before the erase operation is
complete. The read values will be erased until the erase operation is
finished. New erase requests will be rejected until an error(2) or
normal(1) value is obtained.
snAgWriteNVRAM
brcdIp.1.1.2.1.3
Syntax: Integer
Read-write
Saves all configuration information to NVRAM of the agent. The following
values can only be read:
•
normal(1)
•
error(2) – Operation failed or the flash is bad.
•
writing(4) – Agent is writing to NVRAM flash.
•
busy(5) – Operation is not allowed at this time as flash is busy.
The following value can be written:
•
write(3) – Write operation.
The agent returns a response even before the write operation is complete.
The read values will be written until the write operation is finished. New
write requests will be rejected until an error(2) or normal(1) value is
obtained. This object requires a password to be set for the
snAgGblPassword object.
snAgConfigFromNVRA
M
brcdIp.1.1.2.1.4
Syntax: Integer
Read-write
Configures the switch from NVRAM of the agent. The following values can
only be read:
•
normal(1)
•
error(2) – Operation failed or the flash is bad.
•
configing(4) – Configuring from NVRAM flash is in process.
•
busy(5) – Operation is not allowed at this time as flash is busy.
The following value can be written:
•
config(3) – Do configuration.
The agent returns a response after configuration is done. This object
requires a password to be set for the snAgGblPassword object.
NOTE: The object snAgConfigFromNVRAM is obsolete and it is not
supported on any of the NetIron and FastIron devices.