Snagbuildver, Snaggblcpuutil1secavg, Snaggblcpuutil5secavg – Brocade Unified IP MIB Reference (Supporting FastIron Releases 07.5.00 and 08.0.10) User Manual
Page 176: Snaggblcpuutil1minavg, Snaggbldynmemutil, Snaggbldynmemtotal, Snaggbldynmemfree, Snagimgloadspmodulety pe, Snagimgloadspmodulenu mber, Snagtrapholdtime
150
Unified IP MIB Reference
53-1003106-01
Image version
5
snAgBuildVer
brcdIp.1.1.2.1.49
Syntax: DisplayString
Read-only
Shows the image label of the software.
It can display up to 32 characters.
snAgGblCpuUtil1SecAvg
brcdIp.1.1.2.1.50
Syntax: Gauge32
Read-only
Shows CPU utilization every second.
Use snAgentCpuUtilTable on the devices.
snAgGblCpuUtil5SecAvg
brcdIp.1.1.2.1.51
Syntax: Gauge32
Read-only
Shows CPU utilization every five seconds.
Use snAgentCpuUtilTable on the devices.
snAgGblCpuUtil1MinAvg
brcdIp.1.1.2.1.52
Syntax: Gauge32
Read-only
Shows CPU utilization every minute.
Use snAgentCpuUtilTable on the devices.
snAgGblDynMemUtil
brcdIp.1.1.2.1.53
Syntax: Gauge32
Read-only
Shows the system dynamic memory utilization of the device in
percentage units.
NOTE: On Brocade NetIron devices, use the
snAgentBrdMemoryUtil100thPercent object.
snAgGblDynMemTotal
brcdIp.1.1.2.1.54
Syntax: Integer32
Read-only
Shows the total amount of system dynamic memory available in a
device in number of bytes.
NOTE: On Brocade NetIron devices, use the snAgentBrdMemoryTotal
object.
snAgGblDynMemFree
brcdIp.1.1.2.1.55
Syntax: Gauge32
Read-only
Shows the amount of system dynamic memory that is currently
available ina device in number of bytes.
NOTE: On Brocade NetIron devices, use the
snAgentBrdMemoryAvailable object.
snAgImgLoadSPModuleTy
pe
brcdIp.1.1.2.1.56
Syntax: Integer
Read-write
Shows the switch processor module type that receives the
downloaded image:
•
other(1)
•
vm1(2)
•
pos12(3)
•
pos48(4)
•
atm(5)
•
gignpa(6)
•
lp(7)
snAgImgLoadSPModuleNu
mber
brcdIp.1.1.2.1.57
Syntax: Integer32
Read-write
Shows the slot number of a switch processor module that receives
the downloaded image. Setting this object to zero (0) means that the
switch processor modules receives the image.
snAgTrapHoldTime
brcdIp.1.1.2.1.58
Syntax: Integer
Read-write
The number of seconds that traps will be held during device
initialization. Traps are buffered while the device is initialized; they are
sent when the device is back online.
Valid value: 1 - 600
snAgSFlowSourceInterface
brcdIp.1.1.2.1.59
Syntax: InterfaceIndex
Read-write
Identifies the source interface for sFlow packets sent by the device
that is running sFlow Export.
Use the ifIndex value for this object to specify the source interface to
be used. The interface should have an IP address configured for
sFlow. A value of zero (0) indicates that a source interface has not
been configured for sFlow. Port 65534 is used to specify a null port.
Name, OID, and syntax
Access
Description