Proprietary traps
67
NOTE
The traps in the proprietary MIBs include the following lines in their description:
--#TYPE "Brocade Trap: Power Supply Failure"
--#SUMMARY "Power supply fails, error status %d."
--#ARGUMENTS { 0 }
--#SEVERITY MINOR
--#STATE OPERATIONAL
General traps
The table below lists the general traps generated by devices. Refer to the previous sections in this
chapter to determine if traps for a feature must be enabled (for example, OSPF traps must be
enabled) .
Trap name and number
Varbinds
Severity
Description and trap message
snTrapChasPwrSupply
brcdIp.0.1
NOTE: This object has been
replaced by
and
NOTE: This object is not
supported on Brocade
NetIron XMR and
Brocade NetIron MLX
devices. It has been
replaced by the
page 130. Also, this
object is not supported
on the Brocade MLXe
devices.
snChasPwrSupply
Status
Minor
The power supply failed or is not operating
normally.
The value is a packed bit string; the power
supply statuses are encoded into four bits (a
nibble). The following shows the meaning of
each bit:
(Bit 0 is the least significant bit.)
Bit position and meaning
4 to 31- Reserved
3 - Power Supply 2 DC (0=bad, 1=good).
2 - Power Supply 1 DC (0=bad, 1=good).
1 - Power Supply 2 present status (0-present,
1-not present).
0 - Power Supply 1 present status (0-present,
1-not present).
Sample trap message:
Power supply fails, error
status
snTrapLockedAddressViolation
brcdIp.0.2
NOTE: This object is not
supported on the
Brocade NetIron MLX,
Brocade MLXe,
Brocade NetIron XMR,
Brocade NetIron CES,
and Brocade NetIron
CER series devices.
snSwViolatorPortN
umber
snSwViolatorMacA
ddress
Minor
The number of source MAC addresses
received from a port is greater than the
maximum number of addresses configured
for that port.
Sample trap message:
Lock address violation on Port
MAC Address