Brcdswpackageloadstatus, Brcdswpackageupgradealli mages, Package upgrade result table – Brocade Unified IP MIB Reference (Supporting FastIron Releases 07.5.00 and 08.0.10) User Manual
Page 260
234
Unified IP MIB Reference
53-1003106-01
Software licensing
11
Package upgrade result table
The following table contains the objects that indicate the summary of the last upgrade operation
completed on the Brocade NetIron devices.
brcdSwPackageLoadStatus
brcdIp.1.1.2.16.1.1.3
Syntax: Integer
Read-only
Indicates the progress of the upgrade operation.
The operation starts with the “normal(1)” value when
there is no outstanding upgrade process. When an
upgrade process is initiated, the operation is transitioned
to the “started(2)” value and proceeds further. When the
upgrade process stops, whether the operation is
successful or with errors, it returns to the “normal(1)”
value. Finally, the brcdSwPackageLoadResultTable is
populated with the summary of the upgrade process.
•
normal(1)
•
started(2)
•
internalError(3)
•
manifestFileDownloadError(4)
•
manifestFileValidationError(5)
•
downloadingManagementModuleBoot(6)
•
downloadingManagementModuleMonitor(7)
•
downloadingManagementModuleApplication(8)
•
downloadingInterfaceModuleBoot(9)
•
downloadingInterfaceModuleMonitor(10)
•
downloadingInterfaceModuleApplication(11)
•
downloadingInterfaceModuleFpga(12)
•
downloadingFpgaMBridge(13)
•
downloadingFpgaSBridge(14)
•
downloadingFpgaHBridge(15)
•
upgradingManagementModuleBoot(16)
•
upgradingManagementModuleMonitor(17)
•
upgradingManagementModuleApplication(18)
•
upgradingInterfaceModuleBoot(19)
•
upgradingInterfaceModuleMonitor(20)
•
upgradingInterfaceModuleApplication(21)
•
upgradingInterfaceModuleFpga(22)
•
upgradingFpgaMBridge(23)
•
upgradingFpgaSBridge(24)
•
upgradingFpgaHBridge(25)
brcdSwPackageUpgradeAllI
mages
brcdIp.1.1.2.16.1.1.4
Syntax: TruthVal
Read-write
Specifies all images upgrade.
•
true(1) - The upgrade sequence includes MP and LP
boot images and MP FPGA images
(MBRIDGE/MBRIDGE32 and SBRIDGE/HSBRIDGE).
For Brocade NetIron CES and Brocade NetIron CER
series, the upgrade sequence includes only the boot
images.
•
false(2) - Upgrades only MP and LP monitor images,
MP and LP application images, and LP bundled FPGA
images. For Brocade NetIron CES and Brocade
NetIron CER series only the monitor, application, and
FPGA images are upgraded. Returns false(2), for a
read-only operation.
Default: false(2)
Name, OID, and syntax
Access
Description