beautypg.com

Snagentredunbkupcop ybootcode, Snagentenablemgmtm odredunstatechangetr ap, Snagentredunbkupboo tload – Brocade Unified IP MIB Reference (Supporting FastIron Releases 07.5.00 and 08.0.10) User Manual

Page 206: Snagentredunswitchov er, System cpu utilization table

background image

180

Unified IP MIB Reference

53-1003106-01

System CPU utilization table

6

System CPU utilization table

The objects in the following table are not supported on the Brocade MLXe, Brocade NetIron MLX,
Brocade NetIron XMR, Brocade NetIron CES, and Brocade NetIron CER series devices. The objects
are supported on the FastIron devices.

Name, OID, and syntax

Access

Description

snAgentRedunActiveMg
mtMod
brcdIp.1.1.2.10.1.1
Syntax: Integer32

Read-write

Shows the slot number of the active management module. Setting this
object does not take effect immediately. You must save the
configuration data to flash storage, then reboot the system before the
new value takes effect. Setting a value of 0 requests the system to
auto-select an active management module after power up.
Default: 0

snAgentRedunSyncCon
fig
brcdIp.1.1.2.10.1.2
Syntax: Integer32

Read-write

Shows how often the data in the active management module will be
copied
to the backup management module. The value for this object is in
seconds.
Setting this object to 0 disables the copy process. Setting it to a
negative value starts the process immediately, but runs only once.
Default: Every 10 seconds

snAgentRedunBkupCop
yBootCode
brcdIp.1.1.2.10.1.3
Syntax: Integer

Read-write

If enabled, the backup management module copies the boot code of the
active management module to its boot code flash storage after power
up, and whenever the active management module’s boot code is
updated. The backup management module does not copy the boot code
it is identical to what is already in flash storage:

disabled(0)

enabled(1)

Default: disabled(0)

snAgentEnableMgmtM
odRedunStateChangeTr
ap
brcdIp.1.1.2.10.1.4
Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate
management module redundancy state change traps:

disabled(0)

enabled(1)

Default: enabled(1)

snAgentRedunBkupBoo
tLoad
brcdIp.1.1.2.10.1.5
Syntax: Integer

Read-write

Downloads a new boot code from boot flash storage of the active
management module to the backup management module.
In a set operation, enter the value downloadBackup(20) to download
the boot code from the active management module to the backup
management module. A set operation is rejected during a download
until an error or normal state is reached.
One of the following values is returned by a get operation:

normal(1) – No operation.

operationError(17) – Error codes.

downloadBackup(20) – Download boot code from active module to
backup to the backup module.

snAgentRedunSwitchOv
er
brcdIp.1.1.2.10.1.6
Syntax: Integer

Read-write

Switches a backup management module to an active management
module:

other(1)

reset(2) – Resets the backup module to active.

This manual is related to the following products: