The following table manages the temperature for devices that supports the stacking functionality.
Name, OID, and syntax
Access
Description
snChasFan2Table
brcdIp.1.1.1.3.2
NOTE: This object is not
supported on the
NetIron devices.
None
A table of fan information for each unit. Only an installed fan is
displayed in a table row.
snChasFan2Unit
brcdIp.1.1.1.3.2.1.1
Syntax: Integer
Read-only
The unit to the fan table.
snChasFan2Index
brcdIp.1.1.1.3.2.1.2
Syntax: Integer
Read-only
The index to the fan table.
snChasFan2Description
brcdIp.1.1.1.3.2.1.3
Syntax: DisplayString
Read-only
The fan description string. This description can have up to 128
characters.
snChasFan2OperStatus
brcdIp.1.1.1.3.2.1.4
Syntax: Integer
Read-only
The fan operation status:
•
other(1)
•
normal(2)
•
failure(3)
Name, OID, and syntax
Access
Description
snChasUnitTable
brcdIp.1.1.1.4.1
None
A table of information for each unit in a stack. Only an active unit is
displayed in a table row.
snChasUnitIndex
brcdIp.1.1.1.4.1.1.1
Syntax: Integer32
Read-only
The index to the table.
snChasUnitSerNum
brcdIp.1.1.1.4.1.1.2
Syntax: DisplayString
Read-only
The serial number of the unit. If the serial number is unknown or
unavailable, then the value should be a zero length string. There can
be up to 128 characters for the serial number.
snChasUnitNumSlots
brcdIp.1.1.1.4.1.1.3
Syntax: Integer32
Read-only