5

snAgentBrdStatusLeds
brcdIp.1.1.2.2.1.1.8
Syntax: Integer32

Read-only The object is replaced by the object snAgentBrdStatusLedString.

The value of this LED can be one of the following:

0 – off (Link off)

1 – on (Link on)

snAgentBrdTrafficLeds
brcdIp.1.1.2.2.1.1.9
Syntax: Integer32
NOTE: This object is not

supported on the
Brocade MLXe, Brocade
NetIron MLX, Brocade
NetIron XMR, Brocade
NetIron CES, and
Brocade NetIron CER
series devices.

Read-only The object is replaced by the object snAgentBrdTrafficLedString.

The value of this LED can be one of the following:

0 – off (No traffic)

1 – on (Traffic is flowing)

snAgentBrdMediaLeds
brcdIp.1.1.2.2.1.1.10
Syntax: Integer32

Read-only Applies to devices that have an LED for media type, but this object

has been replaced by the object snAgentBrdMediaLedString.
The value of this LED can be one of the following:

0 – Half-duplex

1 – Full-duplex

snAgentBrdSpeedLeds
brcdIp.1.1.2.2.1.1.11
Syntax: Integer32
NOTE: This object is not

supported on the
Brocade MLXe, Brocade
NetIron MLX, Brocade
NetIron XMR, Brocade
NetIron CES, and
Brocade NetIron CER
series devices.

Read-only Applies to devices that have an LED for board speed. This object

has been replaced by the object snAgentBrdSpeedLedString.
The value of this LED can be one of the following:

0 – 10 Mbit

1 – 100Mbit

snAgentBrdModuleStatus
brcdIp.1.1.2.2.1.1.12
Syntax: Integer

Read-only Shows the status of a module:

moduleEmpty(0) – The slot of the chassis is empty.

moduleGoingDown(2) – The module is going down.

moduleRejected(3) – The module is being rejected due to a
wrong configuration.

moduleBad(4) – The module hardware is bad.

moduleConfigured(8) – The module is configured (stacking).

moduleComingUp(9) – The module is in power-up cycle.

moduleRunning(10) – The module is running.

moduleBlocked(11) – The module is blocked for full height
card.

By default, this mode is set to notActivated(0).

snAgentBrdRedundantStatus
brcdIp.1.1.2.2.1.1.13
Syntax: Integer

Read-only Shows the status of the redundant module. Non-management

modules always return other(1).
The management module returns the rest of the states:

other(1)

active(2)

standby(3)

crashed(4)

comingUp(5)

Name, OID, and syntax