beautypg.com

Snospfvirtifstatusrtrdeadin terval, Snospfvirtifstatusstate, Snospfvirtifstatusevents – Brocade Unified IP MIB Reference (Supporting FastIron Releases 07.5.00 and 08.0.10) User Manual

Page 558: Snospfvirtifstatusauthtype, Snospfvirtifstatusauthkey, Snospfvirtifstatusmd5auth keyid, Snospfvirtifstatusmd5auth key

background image

532

Unified IP MIB Reference

53-1003106-01

OSPF virtual interface status table

50

snOspfVirtIfStatusRtrDeadIn
terval
brcdIp.1.2.4.13.1.1.7
Syntax: PositiveInteger

Read-only

Specifies the number of seconds that neighbor routers wait for a
router’s hello packets before they declare that the router is down. This
should be a multiple of the hello interval. This value must be the
same for all routers attached to a common network.
Default: 60 seconds

snOspfVirtIfStatusState
brcdIp.1.2.4.13.1.1.8
Syntax: Integer

Read-only

Shows the state of the OSPF virtual interface:

down(1)

pointToPoint(4)

Default: down(1)

snOspfVirtIfStatusEvents
brcdIp.1.2.4.13.1.1.9
Syntax: Counter32

Read-only

Shows the following:

The number of times that the state of this OSPF interface has
changed

The number of times an error has occurred

snOspfVirtIfStatusAuthType
brcdIp.1.2.4.13.1.1.10
Syntax: Integer32

Read-only

Specifies the authentication type for an interface.
Valid values:

none(0)

simplePassword(1)

reserved for specification by IANA(> 1)

Additional authentication types may be assigned locally on a
per-interface basis.
Default: none(0)

snOspfVirtIfStatusAuthKey
brcdIp.1.2.4.13.1.1.11
Syntax: OCTET STRING

Read-only

Specifies the authentication key:

If the authentication type selected is a simple password, then
this object requires an alphanumeric password. If the value is
shorter than eight octets, the agent will left-adjust and zero-fill
the key to equal eight octets.
The simple password setting takes effect immediately. All OSPF
packets transmitted on the interface contain this password. Any
OSPF packet received on the interface is checked for this
password. If the password is not present, then the packet is
dropped. The password can be up to eight characters long.

If the authentication type is MD5, then a key ID and an MD5 key
are required. The key ID is a number from 1 through 255 and
identifies the MD5 key that is being used. The MD5 key can be
up to 16 alphanumeric characters long.

When read,

“snOspfIfAuthKey”

always returns a blank.

Default: ’0000000000000000’h, which is 0.0.0.0.0.0.0.0

snOspfVirtIfStatusMd5Auth
KeyId
brcdIp.1.2.4.13.1.1.12
Syntax: Integer

Read-only

Specifies the ID of the MD5 authentication key. This object identifies
the algorithm and secret key used to create the message digest
appended to the OSPF packet. Key identifiers are unique per
interface.
If the

“snOspfVirtIfAuthType”

object is set to MD5, the value of this

object must be a number from 1 through 255.

snOspfVirtIfStatusMd5Auth
Key
brcdIp.1.2.4.13.1.1.13
Syntax: OCTET STRING

Read-only

Specifies the MD5 authentication key. The value of this object is
encrypted and included in each OSPF packet transmitted.
If the value of this object is shorter than 16 octets, the agent will
left-adjust and zero-fill the key to equal 16 octets.
When read, snOspfIfMd5AuthKey always returns a blank.