Snchasactualtemperature, Snchaswarningtemperatur e – Brocade Unified IP MIB Reference (Supporting FastIron Releases 07.5.00 and 08.0.10) User Manual
Page 153
Unified IP MIB Reference
127
53-1003106-01
Fan status
4
snChasActualTemperature
brcdIp.1.1.1.1.18
Syntax: Integer
NOTE: This object is
notsupported on
the Brocade MLXe,
Brocade NetIron
XMR, Brocade
NetIron MLX,
Brocade NetIron
CES, Brocade
NetIron CER series
and on the FastIron
devices. Instead
use
Read-only
Applies only to management modules with temperature sensors.
Shows the temperature of the chassis. Each unit is 0.5º Celsius.
NOTE: If you are comparing this value to the value you get when you
enter a show chassis command on the CLI, divide this value by
2. The result is the actual temperature you see in the CLI. This
was done intentionally to represent tenth decimal values in
SNMP, as SNMP can only report INTEGER values.
Valid values: 110 – 250
snChasWarningTemperatur
e
brcdIp.1.1.1.1.19
Syntax: Integer
NOTE: This object is
notsupported on
the Brocade MLXe,
Brocade NetIron
XMR, Brocade
NetIron MLX,
Brocade NetIron
CES, Brocade
NetIron CER series
and on the FastIron
devices. Instead
use
Read/writ
e
Applies only to management modules with temperature sensors.
Shows the threshold for the warning temperature. When the actual
temperature exceeds this value, the switch sends a temperature
warning trap. Each unit is 0.5º Celsius.
Valid values: 0 – 250
NOTE: If you compare the value with the value while entering the show
chassis command and divide the value by 2. The result is the
warning (or shutdown) temperature. This is done intentionally
to represent the tenth decimal values in the SNMP, as the
SNMP can only report the INTEGER values.
Name, OID, and syntax
Access
Description