Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

363

Scenario Batch Files

LeCroy Corporation

Error Checking

The Script Workspace shows errors by red color. The program reports all errors in the log
file.

If you use a script from other InFusion hardware, it may cause an error, for example,
mismatch in hardware Mac addresses, or scenarios that are not already in current
hardware.

Figure 4.51: New Script Window

Log

Results of executable batch commands are saved automatically into a log file with user‐
specified name. The status of executable commands is shown in log area.

Statements

Statements can be conditional statements or non‐conditional statements.

IfIsStopped

Shows whether a scenario is already stopped or not.

Format

IfIsStopped (Serial Number, Target Port)

Parameters

Serial Number: Serial number of hardware

Target Port: Port number in port map

Example

IfIsStopped(ox01267, 1) Then

{

Beep (750, 300)

Run (ox01267," Detect AddressFrame Open", 5)

}

The value of second parameter is 5 and shows check stopping mode of combination of
port number 1 and port number 3.