Exercise and Capture

140

 

 

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

Frame Length Error

Check Frame Length Error, then choose the type of error to introduce.

SOF, EOF and CRC errors

Check these and specify Double or Omit by checking the corresponding option button.

Code violation and Disparity error

Check these and specify DWORD offset and the number of error DWORDs.

Insert Primitive

Check Insert Primitive, click the Type button to open the Primitive Type dialog, then
select the primitive type.

The host can send multiple bursts of HOLD primitives during a single data frame. You can
repeat the HOLD sequence up to 999 times. You can enter the offset between repeats, up
to 99999 DWORDs.

Frame Type Error

Check this to introduce a frame type error.

Drop Link for ... ms

Check this to drop link for the specified milliseconds.

Additionally check:

No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)

Initiator Setting Tab (SAS only)

The Initiator Setting tab allows you to select the Port(s) for generating SAS traffic and to
specify SAS Address, Data Frame Payload size, Frame Receive Timeout, Logical Block size,
and ATA Command Execution Time out (See

Figure 2.139 on page 141

.)

You can run a Pattern Generator. To run the Pattern generator, check the Run Pattern 
Generator
option button and select a Pattern Generator File. You can create Pattern
Generator Files,

See “Creating a Pattern Generator File” on page 449.