Exercise and Capture
140
Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
Frame Length Error
Check Frame Length Error, then choose the type of error to introduce.
SOF, EOF and CRC errors
Check these and specify Double or Omit by checking the corresponding option button.
Code violation and Disparity error
Check these and specify DWORD offset and the number of error DWORDs.
Insert Primitive
Check Insert Primitive, click the Type button to open the Primitive Type dialog, then
select the primitive type.
The host can send multiple bursts of HOLD primitives during a single data frame. You can
repeat the HOLD sequence up to 999 times. You can enter the offset between repeats, up
to 99999 DWORDs.
Frame Type Error
Check this to introduce a frame type error.
Drop Link for ... ms
Check this to drop link for the specified milliseconds.
Additionally check:
No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)
Initiator Setting Tab (SAS only)
The Initiator Setting tab allows you to select the Port(s) for generating SAS traffic and to
specify SAS Address, Data Frame Payload size, Frame Receive Timeout, Logical Block size,
and ATA Command Execution Time out (See
You can run a Pattern Generator. To run the Pattern generator, check the Run Pattern
Generator option button and select a Pattern Generator File. You can create Pattern
Generator Files,