Teledyne LeCroy STX M6-1 SAS_SATA Protocol Analyzer User Manual User Manual
Page 331

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual
329
Scenario Actions
LeCroy Corporation
TABLE 4.3: Test State Actions
Action
Description
Beep
Emits audible sound of duration selectable via
drop‐down list.
Branch to
Existing State
1
Go to a state in this sequence that is already
defined.
1
New State
1
Go to a state in this sequence that is not yet
defined (you need to define it).
1
Capture Data DWORD
Captures a data DWORD into one of four registers.
Inject
CRC Error
Injects a CRC error into the line.
Invalid 10bit‐code
Error
Injects invalid 10b code into the line.
Running Disparity
Error
Injects a Running Disparity (RD) error into traffic.
Insert
Address Frame
FIS Frame
SAS Primitive
SATA Primitive
SMP Frame
SSP Frame
Inserts a frame or primitive.
Insert DWORD
Inserts DWORD.
Link
Disconnect
Puts both InFusion SAS ports at electrical idle
immediately.
Reconnect
Starts traffic pass‐through immediately. This
action restarts traffic after a previous disconnect
command. Once traffic is passing through, the
initiator and target resume OOB signaling.
Monitor/Count
Opens a window to count the number of events
that occur during a session. A session is a time
interval during which a scenario runs.
Remove
Frame Partially
Whole Frame
Removes the targeted event from the traffic.In
InFusion.
A Remove primitive action is implemented by
replacing the primitive with an idle data DWORD.
A Remove frame action is implemented by
replacing the start‐of‐frame and end‐of‐frame
primitives with an idle data DWORD.
Restart
All Sequences
1
Restart all sequences in the scenario.
1
Current Sequence
1
Restart the sequence that contains this action
definition.
1