beautypg.com

Teledyne LeCroy STX M6-1 SAS_SATA Protocol Analyzer User Manual User Manual

Page 331

background image

    

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

329

Scenario Actions

LeCroy Corporation

TABLE 4.3: Test State Actions

Action

Description

Beep

Emits audible sound of duration selectable via
drop‐down list.

Branch to

Existing State

1

Go to a state in this sequence that is already
defined.

1

New State

1

Go to a state in this sequence that is not yet
defined (you need to define it).

1

Capture Data DWORD

Captures a data DWORD into one of four registers.

Inject

CRC Error

Injects a CRC error into the line.

Invalid 10bit‐code
Error

Injects invalid 10b code into the line.

Running Disparity
Error

Injects a Running Disparity (RD) error into traffic.

Insert

Address Frame
FIS Frame
SAS Primitive
SATA Primitive
SMP Frame
SSP Frame

Inserts a frame or primitive.

Insert DWORD

Inserts DWORD.

Link

Disconnect

Puts both InFusion SAS ports at electrical idle
immediately.

Reconnect

Starts traffic pass‐through immediately. This
action restarts traffic after a previous disconnect
command. Once traffic is passing through, the
initiator and target resume OOB signaling.

Monitor/Count

Opens a window to count the number of events
that occur during a session. A session is a time
interval during which a scenario runs.

Remove

Frame Partially
Whole Frame

Removes the targeted event from the traffic.In
InFusion.
A Remove primitive action is implemented by
replacing the primitive with an idle data DWORD.
A Remove frame action is implemented by
replacing the start‐of‐frame and end‐of‐frame
primitives with an idle data DWORD.

Restart

All Sequences

1

Restart all sequences in the scenario.

1

Current Sequence

1

Restart the sequence that contains this action
definition.

1