Exercise and Capture

146

 

 

Sierra M6‐4 SAS/SATA Protocol Analyzer User Manual

Choose Host Emulator Port

For each port, select a speed.

Pattern Generator

You can select a Pattern Generation file. To perform a capture with a Pattern Generator,
enter a path to a pattern generator *.spg file in the File Name dialog. See

“Creating a

Pattern Generator File” on page 449

for instructions how to create a Pattern Generator

file.

Host Emulator

You can run an Host Emulator while setting:

Auto stop exerciser when Analyzer stops

CONT usage

Delay between getting HOLD to Sending HOLDA

Data Frame Payload Size

ATA Command Execution Timeout

Logical Block Size (for ATAPI)

Check Autostop exerciser when Analyzer Stopped to halt the Host Emulator when the
Analyzer stops.

Check CONT Usage to enable the specification of Delay between getting HOLD to 
sending HOLDA
, Data Frame Payload Size, and ATA Command Execution Timeout.

ATA Command Execution Timeout

The ATA Command Execution Timeout is a timeout for ATA commands. When the host
sends an H2D frame (i.e., it issues a command) and receives an R_OK from the device, it
starts this timer. If the execution of the command takes more than the timeout specified
(15 seconds is the default), the host emulator performs the action specified in the
Advanced/General/ ATA command timeout recovery action settings. The options are
Nothing, Send Soft Reset and Hard Reset.