Displaying the full port name for an interface, Displaying the full port, Name for an interface – Brocade BigIron RX Series Configuration Guide User Manual
Page 213

BigIron RX Series Configuration Guide
135
53-1002484-04
Displaying the full port name for an interface
5
Information for the configurable tables appears under the columns shown in bold type. To simplify
configuration, the command parameter you enter to configure the table is used for the table name.
For example, to increase the capacity of the IP route table, enter the following commands.
BigIron RX(config)# system-max ip-route 120000
BigIron RX(config)# write memory
BigIron RX(config)# exit
BigIron RX# reload
NOTE
If you enter a value that is not within the valid range of values, the CLI will display the valid range for
you.
To increase the number of IP subnets you can configure on each port on a device, enter the
following commands.
Syntax: system-max ip-subnet-port <num>
The <num> parameter specifies the maximum number of subnet addresses per port and can be
from 24 – 128. The default is 24.
NOTE
You must reload the software for the change to take effect.
Displaying the full port name for an interface
Using the show interface brief wide command long port names are displayed. If the show interface
brief wide command is not used only partial names are displayed in cases of long port names.
To display the complete port name up to 256 characters for an interface, enter the following
command.
BigIron RX# show interface brief wide
Port Link Port-State Speed Tag MAC Name
1/1 Up Forward 1G No 001b.ed24.3a00 this is a long port
nameqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
qqqqqqqqqqqqqqqq
1/2 Up Forward 1G No 001b.ed24.3a00 this is a long port
nameqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
qqqqqqqqqqqqqqqq
1/3 Down None None Yes 001b.ed24.3a00 this is a long port
nameqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
qqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqqq
qqqqqqqqqqqqqqqq
1/4 Down None None No 001b.ed24.3a00
1/5 Down None None No 001b.ed24.3a00
1/6 Down None None No 001b.ed24.3a00
1/7 Disabled None None No 001b.ed24.3a00
1/8 Disabled None None No 001b.ed24.3a00
BigIron RX(config)# system-max ip-subnet-port 64
BigIron RX(config)# write memory
BigIron RX(config)# exit
BigIron RX# reload