BigIron RX Series Configuration Guide

53-1002484-04

Basic management

39

packets input, bytes,
no buffer

The packets input variable specifies the number of
packets received.

The bytes variable specifies the number of bytes
received.

The no buffer variable specifies the number of packets
with no buffer.

Received broadcasts,
multicasts, unicasts

The variable specifies the amount of traffic the interface
module is receiving on broadcasts, multicasts, and unicast traffic.

input errors, CRC,
frame, ignored

The input errors variable specifies the number of
received packets with errors.

The CRC variable specifies the number of received
packets with CRC errors.

The frame variable specifies the number of received
packets with alignment errors.

The ignored variable specifies the number of received
packets that are discarded.

runts, giants, DMA
received packets

The runts variable specifies the number of small packets
that are less than 64 bytes.

The giants variable specifies the number of large
packets greater than 1518 bytes.

The DMA received packets variable specifies the number
of DMA received packets.

packets output, bytes,
underruns

The packets output variable specifies the number of
packets transmitted.

The bytes variable specifies the number of bytes
transmitted.

The underruns variable specifies the number of packets
that underruns.

Transmitted broadcasts,
multicasts, unicasts

The variable specifies the amount of traffic the interface
module transmitted on broadcasts, multicasts, and unicast traffic.

output errors,
collisions, DMA transmitted
packets

The output errors variable specifies the number of
transmitted packets with errors.

The collisions variable specifies the number of
transmitted packets with collision errors.

The DMA transmitted packets variable specifies the
number of DMA transmitted packets.

Port Translation counter

The variable specifies the total number of port translation
events.

Port UP counter

The variable specifies the total number of times port state
change from down to up.

Port Down Counter

The variable specifies the total number of times port state
change from up to down.

TABLE 182

Output parameters of show interfaces command (Continued)

This field...

Displays...