Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 619
Procedures 12-55
Octel Overture 200/300 Serenade 3.0
PB60014–01
Action
Octel Overture 200/300 Description and Response
The following message is printed.
CPU Model 300–6039–001 Rev 02F
486 Step 27 12MB
Testing Processor...PASSED
Testing System Voltage/Temp...PASSED
Testing ROM Checksum...PASSED
Testing PIT...PASSED
Testing DMA...PASSED
Testing UART...PASSED
Testing Modem...PASSED
Testing TDM Crosspoint...PASSED
Testing Floppy...PASSED
Testing RTC...PASSED
Testing BIC...PASSED
Testing OCC...PASSED
Testing WDT...PASSED
Testing Control Bus Interface...PASSED
Testing COMPLETED
Booting from floppy disk file XBOOT.IM
Image loaded
Loading Image from Floppy Disk
Loading file VMS1_2.IM
Please insert code floppy #2 & Press Return..
Loading file VMS2_2.IM
Image loaded
–––––– SYSTEM SOFTWARE RELEASE S.X.X.X (XX/XX/XX) ––––––
Copyright(c)
199X Octel Communications Corp
.
All Rights Reserved.
TUE 11/08 08:44:58 19XX ID: S/N:000000 PBX:00
(Modem enabled) Last Logon : 00/00 00:00
@WAITING FOR VCU READY
SYSTEM INITIALIZATION SUSPENDED!
At this point the Octel Overture 200/300 has completely booted from
floppy diskette.
Refer to the Hardware Replacement chapter in this volume. Hard disks
may be hot plugged.
To log on to the Octel Overture 200/300.
At the @ prompt enter the slot number for the replaced drive. The VCU
tests the slot and updates its status record.
Repeat
DSKTST
for each drive to be replaced.
7.
Insert Code Floppy #2 when
prompted, press
Enter
Install the hard disk and continue
8.
Install the replacement hard
disk(s).
9.
Press .
Enter
10.
@DSKTST
Enter