Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 39
INSTALL 1-9
Octel Overture 200/300 Serenade 3.0
PB60014–01
If something goes wrong with the message server, it can call and report the problem. This can be an
on- or off-premise number. Include access codes, if necessary. Enter a
D
for a delay after any access
codes you might use. (The length of the delay is determined by System Parameter 28.) Enter an
E
for
“expect dial tone.” Do not use any spaces.
Question 1. f) asks for the string of numbers to be dialed for the forwarding string and the
cancel-forwarding string when the message server is reloading or finished reloading.
f) What is the forwarding string, including destination extension,
to be dialed when the system is reloading and cannot accept calls?
(May include: 0–9,*,#, D=DELAY, E=EXPECT DIAL TONE, or F=FLASH,
1–12 chars, empty line = NONE )
:
What is the cancel–forwarding string, to be dialed when the system
has finished reloading and is ready to accept calls?
(May include: 0–9,*,#, D=DELAY, E=EXPECT DIAL TONE, or F=FLASH,
1–12 chars, empty line = NONE )
:
While the Octel Overture 200/300 is reloading after a power failure, the ports can be forwarded to an
alternate answering point. Enter the code that causes incoming calls to ring at the alternate answering
location. If
NONE
is entered, all ports remain off hook (busy) when the message server is loading or
reloading.
The second part of this question asks for the cancel-forwarding number to be entered, which allows a
return to the Octel Overture 200/300 when the server is again operational.
Question 1. g) asks for the minimum length for all mailbox security codes.
g) Enter the minimum length for all security codes.
(0–10, empty line = 0 )
:
The answer to this question defines the value for System Parameter 144 — MINIMUM LENGTH
FOR SECURITY CODES. The maximum length for a security code is 10 digits.
.
If this is changed after the initial installation, existing security codes with fewer digits are not
affected until the mailbox holder changes the security code.
Question 1. h) asks for the default security code for mailboxes that logon using a mailbox
number.
h) For mailboxes which logon via MAILBOX number (NO port/trunk cos attr 106)
enter the DEFAULT SECURITY CODE.
Note: This code will apply to all mailboxes which do not have a security
code defined.
(xx –10 digits, empty line = NONE )
: