Log options, Pr option, print log files – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 296
7-2
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Log Options
Several log options are available to the user. Details about each option and how it works with each log
type are presented in the following sections.
PR Option, Print Log Files
Use the
LOG
option PR to list filters for each log type. These filters designate the records that can be
collected and displayed.
When you enter
LOG PR [log type]
, the Octel Overture
t200/300 prompts for print options and
filters to control the output format and record selection criteria. The desired combinations of print options
and filters are entered in the command line. The print options are common for all log types; the filters
differ by log type. The PR filters for each log type are explained in the appropriate section.
@LOG PR
Specify Print Option(s):
“S”tart
The general rules for using the
LOG PR x
command to display activities are as follows:
-
Print options and filters for
LOG PR x
can be entered in any order.
-
Print options and filters can be omitted and some might be only partially specified so that a range
that matches the entered characters is displayed.
If no print options or filters are entered after the
LOG PR x
command, all information is printed,
starting at the beginning of the log and ending with the last entry.
.
At any time, press
Escape
to terminate printing and return to the @ prompt.
The print-option fields for setting how the trace is displayed on the screen are explained as follows:
-
Start
[
time]
. Enter the time that the trace log display should begin. Only those activities with a
start time greater than or equal to the specified time are displayed. If no start time is specified, the
display begins at the beginning of the log.
You must specify the year, month, and day. The hour, minute, and second are optional. For example,
S 97 01 23 7
specifies 7 a.m. on January 23, 1997, as the starting time for records to be printed.
-
End
[
time]
. Enter the time that the trace log display should end.
You must specify the year, month, and day. The hour, minute, and second are optional. For example,
E 97 01 23 9 27
specifies 9:27 a.m. on January 23, 1997, as the end time. Records with an
ending time after this time are not printed.
-
Line [length]
. Line length can be shortened if the screen is too small and lines wrap. This will
truncate columns on the right. If the display line length should be changed, enter the line length
desired. The standard line length is 80 characters. The default varies by record type.