4.10 CONNECTING THE PHONE SYSTEM TO THE OCTEL
OVERTURE 200/300
After you have verified that both the message server and the PBX are configured correctly, you must
connect the Octel Overture 200/300 to the PBX.
Connection Overview
The Octel Overture 200/300 installation involves connecting 25-pair cables from the rear of the Octel
Overture 200/300 to a 66M4-4W connector block, which is mounted on a backboard. Each 25-pair cable
supports one slot on the Octel Overture 200/300. The Octel Overture 200/300 is then connected with
jumper wire to the PBX.
It is recommended that the PBX extensions to be associated with the Octel Overture 200/300 be
terminated on a 66M connector block, or equivalent, for ease of installation and fault isolation, as shown
in Figure 4-10.
Figure 4-10 Typical Octel Overture 200/300 Connections
66M4-4W
66M
Cross-connect wire
– – – – – –
– – – – – –
– – – – – –
– – – – – –
– – – – – –
– – – –
– – – –
– – – –
– – – –
– – – –
Bridge clips
25-pair cable
PBX extensions
terminate here
PBX
Octel Overture 200/300
Verifying the Equipment
The following equipment is required for installation of the Octel Overture 200/300:
-
PBX extensions associated with the Octel Overture 200/300, to be terminated on a 66M connector
block, or equivalent
-
Octel Overture 200/300 installation kit
-
DAC installation kit, Part No. 740-6045-001, if installing DAC
Each kit installs four DAC slots. To determine the number of DAC installation kits to order, divide
the total number of DAC slots by four. The kit contains the following:
-
One DAC I/O Panel Assembly, Part No. 740-6051-001
-
One d.c. Power Supply Assembly, Part No. 740-6050-001