Table 8-2 Hardware Error Types and Remedies (continued)

Error Type:Name

Priority

Remedy

Source

DATA-2 =

00

=

NO VOICE FILE SLOTS LEFT

01–06

=

LOGICAL DRIVE ID THAT IS FULL

0a

=

PROMPT AREA FULL

0b

=

NO DISK WITH SUFFICIENT SPACE AVAILABLE

0c

=

SYSTEM RECORDING LIMIT EXCEEDED (ZERO HOUR DRIVES)

DATA-3 =

NOT USED

DATA-4 =

NOT USED

11: Disk Initialization

Failure

VCU could not
successfully initialize
the disk(s).

Contact your technical support center.

3

DATA-1 =

REASON:
01 =

NO SYSTEM DISK FOUND

02 =

NO VALID FILE SYSTEM FOUND

DATA-2 =

NOT USED

DATA-3 =

NOT USED

DATA-4 =

NOT USED

12: CPU Parity

Parity error occurred
in CPU memory area.

If error repeats, replace power supply unit.

3

DATA-1

FROM I/O ADDRESS 6A (ERR.ADDR2)
BIT 0, 1, 2 = CONTEXT REG IN USE ON ERROR

DATA-2

FROM I/O ADDRESS 69 (ERR.ADDR1)
HIGH ADDRESS ON PARITY ERROR

DATA-3

FROM I/O ADDRESS 68 (ERR.ADDR0)
LOW ADDRESS ON PARITY ERROR

DATA-4

CONTENTS OF CONTEXT REG DESIGNATED BY DATA-1

14: VCU initial

checksum error

VCU code checksum
incorrect

Contact your technical support center.

3

15: System Status

Error

Temperature or
voltage out of range

Check DATA-1 for information pertaining
to what is out of range and perform
corrective action.*

3

*

To correct cabinet temperature, check the filter, fan, room
temperature, etc. Be sure there are at least six inches between
cabinet and the wall. If Type 15 errors (with DATA-1=01) still
appear, replace the CPU card. For Type 15 errors (with
DATA-1=02, 03, 04, 05, 06, 0A, or 0B), voltage cannot be
adjusted; recommended action is to replace the power supply
unit.