System Errors and Traffic Pegs 8-7
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
DATA-2 =
00
=
NO VOICE FILE SLOTS LEFT
01–06
=
LOGICAL DRIVE ID THAT IS FULL
0a
=
PROMPT AREA FULL
0b
=
NO DISK WITH SUFFICIENT SPACE AVAILABLE
0c
=
SYSTEM RECORDING LIMIT EXCEEDED (ZERO HOUR DRIVES)
DATA-3 =
NOT USED
DATA-4 =
NOT USED
11: Disk Initialization
Failure
VCU could not
successfully initialize
the disk(s).
Contact your technical support center.
3
DATA-1 =
REASON:
01 =
NO SYSTEM DISK FOUND
02 =
NO VALID FILE SYSTEM FOUND
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
12: CPU Parity
Parity error occurred
in CPU memory area.
If error repeats, replace power supply unit.
3
DATA-1
FROM I/O ADDRESS 6A (ERR.ADDR2)
BIT 0, 1, 2 = CONTEXT REG IN USE ON ERROR
DATA-2
FROM I/O ADDRESS 69 (ERR.ADDR1)
HIGH ADDRESS ON PARITY ERROR
DATA-3
FROM I/O ADDRESS 68 (ERR.ADDR0)
LOW ADDRESS ON PARITY ERROR
DATA-4
CONTENTS OF CONTEXT REG DESIGNATED BY DATA-1
14: VCU initial
checksum error
VCU code checksum
incorrect
Contact your technical support center.
3
15: System Status
Error
Temperature or
voltage out of range
Check DATA-1 for information pertaining
to what is out of range and perform
corrective action.*
3
*
To correct cabinet temperature, check the filter, fan, room
temperature, etc. Be sure there are at least six inches between
cabinet and the wall. If Type 15 errors (with DATA-1=01) still
appear, replace the CPU card. For Type 15 errors (with
DATA-1=02, 03, 04, 05, 06, 0A, or 0B), voltage cannot be
adjusted; recommended action is to replace the power supply
unit.