Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
64. LAN Card
Hardware Error
(continued)
Problem detected by
the LAN card.
Dependent on the DATA-1 values described
below.
3
DATA-2 values in case of LAN_LOST_COMM:
1
Unable to read card status.
2
Card status is nonoperational.
3
CB timed out at start of read reply.
4
CB timed out during read reply packet.
5
CB time out at start of send request.
6
CB timed out when checked if took request.
7
CB timed out at end of the read reply.
8
CB timed out during write request packet.
9
CB timed out after write request.
1 0
Complement of replies not match.
1 1
Checksum wrong after control bus copy.
03 = REACHED THE MAX. RETRY COUNT WHILE SYNCHRONIZING.
FORCED RESET DONE TO SYNCHRONIZE.
The CPU is unable to communicate with the LAN card.
REMEDY:
Same as for DATA-1 = 02.
04 = LAN CONTROL BLOCK REQUEST SIZE MISMATCH
Compatibility problem with the LAN card.
REMEDY:
Contact your technical support center.
05 = LAN CONTROL REPLY BLOCK SIZE MISMATCH
Compatibility problem with the LAN card.
REMEDY:
Contact your technical support center.
06 = LAN CONTROL BUS TIME OUT DURING READING/WRITING
CONTROL BUS
Problem with the LAN card.
REMEDY:
Contact your technical support center.
07 = OEM NCK OF OTHER SYSTEM DOES NOT MATCH OURS
OEM type between systems is incompatible.
REMEDY:
Use the
LANSTAT
command to determine which location
is in the OEM-FAIL state. Check the OEM type of the