beautypg.com

2 how to configure the dtic, System parameters – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual

Page 495

background image

DTIC 10-3

Octel Overture 200/300 Serenade 3.0

PB60014–01

10.2 HOW TO CONFIGURE THE DTIC

For the DTIC to operate correctly, the Octel Overture 200/300 for the DTIC must be configured correctly.
The major items for configuration are the following:

-

System Parameters

-

COS

-

SLOTS Table

.

The correct LSP Table must be selected during configuration of the SLOTS Table. The LSP
Table, with the name ACULAB, first must be added and configured at a password level higher
than Maintenance level.

Special information regarding integration and configuration, including information about the
LSP Table, is provided in the integration document DPNSS–ACULAB–03/96.

System Parameters

Several system parameters must be properly set to allow the DTIC to work correctly:

-

System Parameter 3 — PBX TYPE and PBX MODEL.
Set the PBX type and PBX model to the correct settings.

-

System Parameter 9 — FLASH TIME (MSEC).
Set the flash time to 130 msec.

-

System Parameter 13
Set the five parts of this parameter. The settings are PBX dependent.

-

TRANSFER INITIATE CODE

-

RECONNECT CODE AFTER NO-ANSWER

-

RECONNECT CODE AFTER BUSY

-

RECONNECT CODE AFTER FAST BUSY

-

TRANSFER COMPLETE CODE

-

System Parameter 51 — RS-232 INTEGRATED WITH PBX.
Does not have to be integrated to work. The setting is site dependent.

-

System Parameter 77 — PBX PROVIDES MOMENTARY DISCONNECT.
Set to

YES

.

-

System Parameter 117 — RINGBACKS BEFORE ANSWERING AX PORT.
Set to

3

,

4

, or

5

for integrated systems or to

0

if not integrated. This setting is site specific and

depends on customer preference.