2 how to configure the dtic, System parameters – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 495

DTIC 10-3
Octel Overture 200/300 Serenade 3.0
PB60014–01
10.2 HOW TO CONFIGURE THE DTIC
For the DTIC to operate correctly, the Octel Overture 200/300 for the DTIC must be configured correctly.
The major items for configuration are the following:
-
System Parameters
-
COS
-
SLOTS Table
.
The correct LSP Table must be selected during configuration of the SLOTS Table. The LSP
Table, with the name ACULAB, first must be added and configured at a password level higher
than Maintenance level.
Special information regarding integration and configuration, including information about the
LSP Table, is provided in the integration document DPNSS–ACULAB–03/96.
System Parameters
Several system parameters must be properly set to allow the DTIC to work correctly:
-
System Parameter 3 — PBX TYPE and PBX MODEL.
Set the PBX type and PBX model to the correct settings.
-
System Parameter 9 — FLASH TIME (MSEC).
Set the flash time to 130 msec.
-
System Parameter 13
Set the five parts of this parameter. The settings are PBX dependent.
-
TRANSFER INITIATE CODE
-
RECONNECT CODE AFTER NO-ANSWER
-
RECONNECT CODE AFTER BUSY
-
RECONNECT CODE AFTER FAST BUSY
-
TRANSFER COMPLETE CODE
-
System Parameter 51 — RS-232 INTEGRATED WITH PBX.
Does not have to be integrated to work. The setting is site dependent.
-
System Parameter 77 — PBX PROVIDES MOMENTARY DISCONNECT.
Set to
YES
.
-
System Parameter 117 — RINGBACKS BEFORE ANSWERING AX PORT.
Set to
3
,
4
, or
5
for integrated systems or to
0
if not integrated. This setting is site specific and
depends on customer preference.