10-14
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Channel Status – ALL — state of the card
Field
Possible values
Description
CARD STATE
UP
DOWN
Card is ready for traffic.
Card is not ready for traffic.
The CARD STATE should agree with the
Traffic field under the TRANSMIT section
of the trunk status.
SEQUENCER PC*
Value from 00 to ff (hex)
Informational only — for use by Octel
Engineering.
CLOCK MASTER
Enabled
Disabled
DTIC enabled as clock master.
DTIC not enabled as clock master.
CLOCK ACTIVE
Enabled
Disabled
A good clock is being received from the
network.
A good clock is not being received from the
network.
* A Sequencer PC is a virtual software entity (like a little computer) that has its own task to perform on a specific part of the card’s
software. For example, there is a separate Sequencer PC for keeping track of the health of each port.
Following is the port status for port 1:
dtic>ST 1
––––– Channel 01 Status –––––––––––––––––––––––––––––––––––––––––––––––––––––––––
RECEIVE
TRANSMIT
ABCD: 0000
ABCD: 1111
OTHER
CHANNEL STATE:
ON HOOK
SEQUENCER PC:
0f
The port status indicates that code 1111 is being sent. This code occurs because the card is down and the
DTIC is not ready to receive a call from the PBX. The SEQUENCER PC status 0f indicates that the port
is waiting to be told to operate. Generally, 0f means down. The following gives basic information about
the fields for the status of a port (channel).
Field
Possible values
Description
Channel 01 Status
RECEIVE
ABCD
.
ABCD represents bit
patterns (range
0000–1111). Given here
are a few common
patterns. Other patterns
would be for unusual
circumstances.
0001
1101
0101
1101
→
1001
→
1101
0000
Idle/on-hook.
Off-hook.
Busy/error.
Flash.
No information or an invalid pattern