System Errors and Traffic Pegs 8-29
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
63. Fax Card
Hardware Error
Fax loopback test
failed, or fax card
didn’t respond to test
command,
TEST X
x
y
z
.
Replace the fax card and do the loopback
test again.
2
DATA-1 =
00 = FAX LOOPBACK TEST FAILED
DATA-2 =OTHER CH# (RELATIVE) USED IN TEST
DATA-3 =ERROR CODE RETURNED FROM FAX PROCESSOR
01 = FAX CARD DIDN’T RESPOND TO TEST COMMAND
DATA-2 =1ST CH# (RELATIVE) USED IN TEST
DATA-3 =2ND CH# (RELATIVE) USED IN TEST
64. LAN Card
Hardware Error
Problem detected by
the LAN card.
Dependent on the Data-1 values described
below.
3
DATA-1 =ERROR CODE:
00 = INVALID LAN CONTROL BUS ID
Problem with LAN card.
REMEDY:
Contact your technical support center.
01 = BAD LAN CONTROL BUS CKSUM
Problem with LAN card.
REMEDY:
Contact your technical support center.
02 = LOST COMMUNICATION TO LAN BOARD
Communication between the CPU and LAN card across the control
bus was interrupted or failed for some reason.
REMEDY:
Verify that the LAN card is properly inserted in the slot
and has not been removed. Try the
LANSTAT
command
to verify that the LAN card is up and communicating
with the CPU. If the error continues, contact your
technical support center.