SLOW BUSY MAXIMUM TONE ON PERIOD
This delay is the longest delay that a TONE ON can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE ON is longer than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MINIMUM TONE ON PERIOD
This delay is the shortest delay that a TONE ON can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE ON is shorter than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MAXIMUM TONE OFF PERIOD
This delay is the longest delay that a TONE OFF can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE OFF is longer than this delay, the message server
assumes that it is not a slow-busy tone.
SLOW BUSY MINIMUM TONE OFF PERIOD
This delay is the shortest delay that a TONE OFF can be to qualify as a slow-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a slow-busy tone. If the TONE OFF is shorter than this delay, the message
server assumes that it is not a slow-busy tone.
FAST BUSY MAXIMUM TONE ON PERIOD
This delay is the longest delay that a TONE ON can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE ON is longer than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MINIMUM TONE ON PERIOD
This delay is the shortest delay that a TONE ON can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE ON is shorter than this delay, the message server
assumes that it is not a fast-busy tone.
FAST BUSY MAXIMUM TONE OFF PERIOD
This delay is the longest delay that a TONE OFF can be to qualify as a fast-busy tone.
Use — The message server uses this delay to determine whether the tone cadences that it is
monitoring is a fast-busy tone. If the TONE OFF is longer than this delay, the message server
assumes that it is not a fast-busy tone.