4-50
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
4.11 OCTEL OVERTURE 200/300 TESTING
The Octel Overture 200/300 should always be checked for proper operation after the configuration
database is installed or changes are made. In addition to the message-server test, other tests should be
made before the Octel Overture 200/300 is connected. These tests are described in this section. The tests
require the following equipment:
-
Three touchtone telephones; label the telephones as telephone A, telephone B, and telephone C
-
One terminal, directly connected to the Octel Overture 200/300, SP1 or J1, with an RS-232C cable
-
One hard copy of the configuration database
-
Two extensions for testing, connected to RJ11 jacks (in addition to the extension associated with the
Octel Overture 200/300
)
-
One modular adapter, Arminger 8-position modular adapter, Part No. AA-2560A, or equivalent, is
recommended
.
These tests assume that no other calls are being made to the Octel Overture 200/300. If calls are
received, the port status could become confusing and might affect the test results.
Operational Test To Verify Dial Tone on PBX Extensions
Verify that dial tone is present on each PBX extension associated with the Octel Overture 200/300, as
follows:
1.
Disconnect the 25-pair cables from the back of the Octel Overture 200/300.
2.
Connect the modular adapter to the 25-pair cable associated with slot one.
3.
Connect a touch-tone single-line telephone to the first jack position of the adapter.
.
Only the first four jack positions of the modular adapter are used for each cable.
4.
Go off-hook. Is dial tone present?
YES
'
Continue for all extensions and cables, for each slot configured in the message
server. Proceed to the test in the next section.
NO
'
Determine the cause and correct the problem before continuing.
Extension Number Check
Verify that the PBXextension numbers match the Octel Overture 200/300 SLOTS Table, as follows:
1.
Refer to the configuration database listing, specifically to the SLOTS Table.
2.
Connect the telephone labeled B to the modular-adapter position associated with port 1.
3.
Connect the telephones labeled A and C to the two test telephone RJ11 jacks.
4.
From telephone A, enter the extension number associated with telephone B.
5.
Does telephone B ring?
YES
'
Answer the call, verify the circuit quality, and move telephone B to the next Octel
Overture 200/300 RJ11. Continue the procedure until all extensions are tested, then
proceed to the test in the next section.
NO
'
Determine the cause and correct the problem before continuing.