System Errors and Traffic Pegs 8-31
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
64. LAN Card
Hardware Error
(continued)
Problem detected by
the LAN card.
Dependent on the DATA-1 values described
below.
3
08 = ERROR DURING COURTESY DOWN
An error occurred while executing the courtesy down command.
DATA-2 =
ERROR CODES:
01
=
COURTESY DOWN STATE
02
=
COURTESY STATE STATE
DATA-3 =
ERROR CODES
01
=
LAN EVENT TIMEOUT
02
=
VCU EVENT TIMEOUT
03
=
INVALID LAN SLOT
REMEDY:
Try the courtesy down command again. If the problem
continues, contact your technical support center.
1
09 = ERROR WITH CSX PARAMETERS
The VCU is unable to provide the necessary client, server, and
transfer-task resources needed to run LAN. This could
typically occur when LAN is added to an existing
installed message server.
DATA-2 =
NUM_CLIENTS (REPORTED BY VCU)
DATA-3 =
NUM_SERVERS (REPORTED BY VCU)
DATA-4 =
NUM_XFERS (REPORTED BY VCU)
REMEDY:
If necessary, System Parameters 126, 127, and 128 can be
set to reduce the CSX request to the VCU. Most likely,
though, the VCU is too old to work with LAN or has
insufficient memory. Contact your technical support
center.
3
A = MULTIPLE YES RESPONSE TO MAILBOX QUERY
Within a LAN uniform numbering plan, any specific mailbox should
have only one occurrence across the domain. The system,
however, sent a mailbox query and had multiple locations
respond with a “found.”
DATA-2 =
MAILBOX NUMBER (DIG 0 AND 1 PACKED)
DATA-3 =
MAILBOX NUMBER (DIG 2 AND 3 PACKED)
DATA-4 =
MAILBOX NUMBER (DIG 4 AND 5 PACKED)
REMEDY:
Use the
FINDMBX
command to locate all occurrences of
the mailbox in question. Delete the unnecessary
occurrence of the mailbox. If this mailbox must appear
multiple times, the numbering plan must be modified to
remove the mailbox initial digits from the uniform
numbering plan domain.