Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 384
8-14
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
28: ACP Error
Works requesting an
error be logged in the
Works Hardware Error
Table
Log onto Works and list the Hardware
Error Table. Refer to the Works Installation
and Maintenance Manual, Maintenance
chapter.
3
29: DMA Timeout
Non-maskable
interrupt
Contact your technical support center.
3
30: Arbitration
Timeout
Non-maskable
interrupt
Contact your technical support center.
3
31: Control BUS
Error
Non-maskable
interrupt
Contact your technical support center.
3
32: CPU Coprocessor
Error
Error logged by
coprocessor interrupt
routines and by
coprocessor Task
Contact your technical support center.
2
DATA-1 =
TYPE OF ERROR THAT OCCURRED IN THE COPROCESSOR
01 = COPROCESSOR INITIALIZATION ERROR
DATA-2
gives the reason.
DATA-2 =
3D =
DUAL PORT RAM READ/WRITE TEST FAILED
3E =
DUAL PORT RAM VERIFY TEST FAILED
3F =
STATIC RAM READ/WRITE TEST FAILED
40 =
STATIC RAM VERIFY TEST FAILED
41 =
UNEXPECTED INTERRUPT RECEIVED BY
COPROCESSOR
42 =
UNEXPECTED NMI RECEIVED BY
COPROCESSOR
43 =
COPROCESSOR EXECUTED A WILD JUMP
44 =
TIMED OUT WAITING FOR COPROCESSOR
READY
02 =
TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 1 TO
COMPLETE
03 =
TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 2 TO
COMPLETE
04 =
COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 1
05 =
COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 2