2 installing and configuring the lan card, Slots table – Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 518
11-2
Installation and Maintenance Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
11.2 INSTALLING AND CONFIGURING THE LAN CARD
Only one LAN card can be installed in the message server. The LAN card can be installed in slots A5,
A6, or A7 for the Octel Overture 200 and slots A10, A11, or A12 for the Octel Overture 300.
The LAN card must be configured in the SLOTS Table and certain system parameters might need to be
modified before the LAN card is installed.
Before installing the LAN card, configure the LAN card in the SLOTS Table. Refer to the Configuration
volume, Slots Table chapter.
SLOTS Table
When adding the LAN card to the SLOTS Table, enter 22 for the card type. The LAN card entry can also
be added in the INSTALL program, question 3, or in
UPDATE
, with the
ADD SLOT
command.
You cannot configure more than one LAN card in the SLOTS Table. Any attempt to add a second LAN
card results in the following error message:
LAN CARD ALREADY CONFIGURED IN SLOT n.
You can install the LAN card in slots A5, A6, or A7 in the Octel Overture 200 and in slots A10, A11, or
A12 of Shelf A in the Octel Overture 300. The commands
MODIFY SLOT
and
DELETE SLOT
allow a
slot with card type 22 to be modified or deleted, respectively.
You cannot modify or delete the LAN card entry in the SLOTS Table when the LAN card is UP. Any
attempt to do so results in the following error message:
LAN is currently UP.
Please COURTESY DOWN the LAN board before doing this operation.