Reliant Octel 200 and Octel 300 Message Servers PB6001401 User Manual
Page 389
System Errors and Traffic Pegs 8-19
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
Priority
Remedy
Source
34: Power-ON
Diagnostic Error
(continued)
Selftest for VCU.
DATA-1 through
DATA-4 designate
errors found
Replace VCU.
3
DATA-3
Bit 0:
Port Controller failed diagnostic selftest.
Bit 1:
Port Controller interrupt functionality failed.
Bit 2:
Port Controller ALU failed.
Bit 3:
Port Controller carry logic failed.
Bit 4:
Port Controller failed to return diagnostic acknowledgement.
Bit 5:
Port Controller failed PLAY/RECORD loop back test.
Bit 6:
Port Controller failed Silence register loop back test.
Bit 7:
DMA controller error detected.
DATA-4
Bit 0:
Watch Dog Timer circuit failed.
Bit 1:
Master interrupt circuit failed.
Bit 2:
Control Bus Status Register circuit failed.
Bit 3:
SCSI Controller circuit failed.
Bit 4:
Undefined.
Bit 5:
Undefined.
Bit 6:
Undefined.
Bit 7:
Undefined.
36. System RAM
Error
Cache module found
an error with system
RAM, CPU and/or
VCU.
Call your technical support center for
remedy.
3
The DATA-1 field specifies the type of error. DATA-2 through DATA-4 are data
associated with the error.
DATA-1 =
ERROR CODE:
01 =
FIRMWARE REPORT OF RAM SIZE NOT EVEN MEGABYTE
02 =
CANNOT R/W MEM AS REPORTED BY FIRMWARE, SEE DATA-2
DATA-2: (D) = MEGABYTES WHERE ERR, WHEN DATA=1 OR 2
03 =
RAM SIZE LESS THAN STANDARD SIZE OF 5 MEG FOR THE
OCTEL OVERTURE 300 AND 2 MEG FOR THE OCTEL OVERTURE 200
(slot = CPU)