System Errors and Traffic Pegs 8-19

Octel Overture 200/300 Serenade 3.0

PB60014–01

Table 8-2 Hardware Error Types and Remedies (continued)

Error Type:Name

Priority

Remedy

Source

34: Power-ON

Diagnostic Error
(continued)

Selftest for VCU.
DATA-1 through
DATA-4 designate
errors found

Replace VCU.

3

DATA-3

Bit 0:

Port Controller failed diagnostic selftest.

Bit 1:

Port Controller interrupt functionality failed.

Bit 2:

Port Controller ALU failed.

Bit 3:

Port Controller carry logic failed.

Bit 4:

Port Controller failed to return diagnostic acknowledgement.

Bit 5:

Port Controller failed PLAY/RECORD loop back test.

Bit 6:

Port Controller failed Silence register loop back test.

Bit 7:

DMA controller error detected.

DATA-4

Bit 0:

Watch Dog Timer circuit failed.

Bit 1:

Master interrupt circuit failed.

Bit 2:

Control Bus Status Register circuit failed.

Bit 3:

SCSI Controller circuit failed.

Bit 4:

Undefined.

Bit 5:

Undefined.

Bit 6:

Undefined.

Bit 7:

Undefined.

36. System RAM

Error

Cache module found
an error with system
RAM, CPU and/or
VCU.

Call your technical support center for
remedy.

3

The DATA-1 field specifies the type of error. DATA-2 through DATA-4 are data
associated with the error.

DATA-1 =

ERROR CODE:

01 =

FIRMWARE REPORT OF RAM SIZE NOT EVEN MEGABYTE

02 =

CANNOT R/W MEM AS REPORTED BY FIRMWARE, SEE DATA-2
DATA-2: (D) = MEGABYTES WHERE ERR, WHEN DATA=1 OR 2

03 =

RAM SIZE LESS THAN STANDARD SIZE OF 5 MEG FOR THE
OCTEL OVERTURE 300 AND 2 MEG FOR THE OCTEL OVERTURE 200
(slot = CPU)