DTIC 10-13

Octel Overture 200/300 Serenade 3.0

PB60014–01

Timeslot 16 Signaling Channel Status — state of only this channel

Field

Possible values

Description

RECEIVE

State

In frame
Out of frame

Normal operation.
Can send voice data but not information regarding
call progress, etc.

MF RAI (Multi-Frame
Remote Alarm Indication)

OFF

ON

Far end satisfied with signal on this channel.
Far end not satisfied.

AIS (Alarm Indication
Signal)

OFF
ON

Normal.
Problem with far end sending pattern, cannot make
phone calls.

TRANSMIT

Mode

CAS

CAS (Channel Associated Signaling) is the only
mode currently.

MF RAI (Multi-Frame
Remote Alarm Indication)

OFF

ON

DTIC satisfied with signal being received.
DTIC not satisfied with signal being received.

AIS (Alarm Indication
Signal)

OFF
ON

Normal.
Problem.

CM State*

State

On-line
Off-line

Normal.
Not functioning. For example, the card may be
off-line for 20–30 minutes when the system is
being booted. The card doesn’t think the system
knows the card is there.

.

When the card is being brought up, the CM
State normally starts off-line for 10 seconds
to 30 minutes, depending on whether the
system software is already up or not.

* Card Manager (CM) is the basic high-level software for the DTIC card.

Both the card and port status also indicate problems. Following is the status card listing:

dtic>ST CARD
––––– Channel Status – ALL –––––––––––––––––––––––––––––––––––––––––––––––––––––––

CARD STATE:

DOWN

SEQUENCER PC:

C2

CLOCK MASTER:

Disabled

CLOCK ACTIVE:

Disabled

The card status explicitly says that the card is DOWN, although the reason is not given. The reason is
given in the trunk status. Also, the card is not actively configured as a clock master (that is, the status is
“Disabled”) by the system, a consequence of the card being down. The following gives basic information
about the fields for the status of the card.